Technical data
and start-up
EVB1-350/400-40-HP
48
7.3.5
Pin 5 PWMP / PWM-out
INFORMATION
This PWM-controlled outlet may be charged with 4 A max. (at 12 V)! Programming is carried out
using the software PARAM.
Internal wiring
15µH
4A
165
µ
F
Pin 5
PWMP
External
Supply
30V
Via this pin, an external pump can be driven up to 4 A / 12 V, which is controlled by the BMS.
Desired temperature thresholds (switching on / switching off) along with the output can be configured in the
10.3 Changing the CAN Parameters with PARAM.
7.3.6
Pin 9 CAN1L, Pin 10 CAN1H
The CAN interface (pin 10) has the following features and/or possibilities:
CAN 2.0 B, 500 kbit (optionally 1 Mbit)
Parameters can be set for CAN IDs.
Termination of the CAN wiring (optional setting of the 120
Ω terminating resistor)
Internal wiring
47p
F
Pin 9 CAN1L
Pin 10 CAN1H
51µH
0,5A
33V
CAN
Driver