3-1
3.1 Safety
Precautions
•
When conducting disassembly operations, place the unit on a grounded anti-static
sheet. LSI and other electronic components are sensitive to static electricity and
may be damaged if touched while charged.
•
Before transporting a circuit board, wrap it in a conducting sheet such as aluminum
foil.
•
When using a soldering iron or other heat-producing tool, ensure that heat does not
damage wires, circuit boards, or plastic parts such as covers.
•
Take care not to lose small screws or washers removed when replacing parts.
•
As a safety precaution, wear gloves when conducting disassembly operations.
3.2 Removing the Film Cartridge
1. Open the top cover and move the Y-cutter arm as far as possible to the left.
2. Push the Set buttons R/L in the direction indicated by the arrow to unlock the Roller
holder assy.
Top cover
Y-cutter arm
Set button R/L
Fig. 3.2-1
Removing the Film Cartridge 1
Содержание LX-1200
Страница 1: ...SERVICE MANUAL MODEL LX 1200 LX 300 ...
Страница 2: ...COOL LAMINATOR SERVICE MANUAL MODEL LX 1200 LX 300 ...
Страница 5: ...Chapter 1 SPECIFICATIONS ...
Страница 9: ...Chapter 2 MECHANISMS ...
Страница 20: ...Chapter 3 DISASSEMBLY PROCEDURES ...
Страница 58: ...Chapter 4 ASSEMBLY PROCEDURES ...
Страница 105: ...Chapter 5 ELECTRONIC CONTROLLERS ...
Страница 127: ...Chapter 6 MAINTENANCE ...
Страница 149: ...Chapter 7 TROUBLESHOOTING ...
Страница 174: ...APP 1 Appendix Main PCB Circuit Diagram ...
Страница 175: ...July 2000 86S006BE0 Printed in Japan ...