14.4
Diagnostic messages of the application
All diagnostic messages that refer to technology functions are indicated via
the diagnostic code (P‑0‑1300) and the diagnostic text (P‑0‑1387).
The various diagnostic messages are subdivided into four categories, which
are an integral part of the relevant diagnostic code. Errors und warnings trig‐
ger corresponding diagnostic messages in IndraDrive, whereas messages
are diagnosed exclusively via the parameters of the technology function.
System event (events) are classified into 4 categories according to their se‐
verity:
●
Stop 0 (event of highest severity)
●
Stop 1
●
Warning
●
Message (event of lowest severity)
The diagnostic number has to be interpreted as follows:
●
B4XXX: Events of category “message”
●
B5XXX: Events of category “warning”
●
D4XXX: Events of category “Stop 1”
●
D5XXX: Events of category “Stop 0”
●
XXX: Number of the event (HEX...FFF)
Every diagnostic message that is related to an event consists of a diagnostic
message number and a diagnostic text.
Example: 404E: "Oil temperature exceeds alarm level"
This note refers to the diagnostic messages of the following table.
Before corrections are made in the form of parameter changes,
first the physical causes of the error should be searched for and
examined.
Increasing alarm or warning thresholds or suppression cycles be‐
fore the actual cause has been eliminated can lead to damage to
the self-contained servo-hydraulic linear axis. This type of param‐
eters should be optimized exclusively by Bosch Rexroth or by au‐
thorized and qualified personnel of a specialized company that
was authorized by Bosch Rexroth, see also
cation of personnel" on page 10
Error/warning,
diagnostic
code: Text
Cause
Remedy
F2011, error, category: Stop
1
F2011, 01: FBS Vlv1 fail
Feedback of the NC and the NO
contact of safety valve 1 provided
the same potential after the de‐
bounce time has elapsed.
Check feedback signals P-0-1296 bit 0 and 1
Check the cable and plug-in connection of the feed‐
back signals of safety valve 1
Check the feedback contacts of safety valve 1
If required, replace cable, connector or safety valve
Operating Instructions
Bosch Rexroth AG
79/91
Self-contained servo-hydraulic linear axis Type SHA...
Troubleshooting
Содержание Rexroth SHA Series
Страница 1: ...Self contained servo hydraulic linear axis Type SHA Operating Instructions RE 62266 B_12 18 Edition 1 ...
Страница 6: ...Bosch Rexroth AG Operating Instructions IV 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 20: ...Bosch Rexroth AG Operating Instructions 18 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 48: ...Bosch Rexroth AG Operating Instructions 46 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 60: ...Bosch Rexroth AG Operating Instructions 58 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 68: ...Bosch Rexroth AG Operating Instructions 66 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 74: ...Bosch Rexroth AG Operating Instructions 72 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 76: ...Bosch Rexroth AG Operating Instructions 74 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 78: ...Bosch Rexroth AG Operating Instructions 76 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 86: ...Bosch Rexroth AG Operating Instructions 84 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 88: ...Bosch Rexroth AG Operating Instructions 86 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 90: ...Bosch Rexroth AG Operating Instructions 88 91 Self contained servo hydraulic linear axis Type SHA ...
Страница 93: ...Notes Operating Instructions Bosch Rexroth AG 91 91 Self contained servo hydraulic linear axis Type SHA ...