![BOC Edwards iL600 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/boc-edwards/il600/il600_instruction-manual_2781982054.webp)
3.7
Check the pump oil-levels
CAUTION
Ensure that the oil-levels in the LCDP pump and the LCMB pump (in an iL600 system)
are correct. If a pump oil-level is incorrect, pump performance may be affected and the
pump may be damaged.
3.7.1
iL70 systems
The iL70 system is supplied with the LCDP pump filled with oil. However, we recommend that
you check the oil-level before you operate the iL system; use the method described below.
Refer to Figure 1-1. Check the oil-level against the MAX mark (see detail B) on the bezel of the
LCDP oil-level sight-glass (10):
•
If the oil-level is above the MAX mark, drain excess oil from the pump as described in
Section 6.8 until the oil-level is correct.
•
If the oil-level is below the MAX mark, fill the pump with oil until the oil-level is correct, as
described in Section 6.8.
3.7.2
iL600 systems
The iL600 system is supplied with both the LCDP and LCMB pumps filled with oil. We
recommend that you check the LCDP and LCMB oil-levels as described below.
1.
Check the LCDP pump oil-level: refer to Section 3.7.1.
2.
Refer to Figure 1-1. Check the oil-level against the MAX mark (see detail B) on the bezel of
the LCMB oil-level sight-glass (4):
•
If the oil-level is above the MAX mark, drain excess oil from the pump as described in
Section 6.9 until the oil-level is correct.
•
If the oil-level is below the MAX mark, fill the pump with oil until the oil-level is correct,
as described in Section 6.9.
3.8
Install or replace the Pump Display Module and other optional accessories
(if necessary)
3.8.1
Install the Pump Display Module (optional)
1.
Unpack and inspect the Pump Display Module.
2.
Refer to Figure 3-6. Remove the blanking panel (1) from the front panel (2).
3.
Fit the connector (4) on the end of the cable (6) to the module connector (3) in the recess (5) in
the front panel.
(Contined on Page 3-12)
iL Dry Pumping Systems
3-11
Содержание iL600
Страница 18: ...iL Dry Pumping Systems 1 9 Figure 1 3 Schematic diagram of the electrical system...
Страница 21: ...1 12 iL Dry Pumping Systems Figure 1 4 Services and electrical connections on the rear of the iL system...
Страница 23: ...1 14 iL Dry Pumping Systems Figure 1 5 Electrical components shown without enclosure for clarity...
Страница 71: ...3 28 iL Dry Pumping Systems...