![BOC Edwards iL600 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/boc-edwards/il600/il600_instruction-manual_2781982039.webp)
2.5
Lubrication
Note:
A BOC Edwards Material Safety Data Sheet for the oil referenced in the following sections is
available on request.
2.5.1
LCDP pump
Gearbox
Oil charge
0.75 litres (typical)
Grade of oil
SAE 40
ISO viscosity grade
150
Recommended perfluoropolyether oils
Fomblin 25/6, Krytox 1525, Drynert 25/6
2.5.2
LCMB pump (iL600 only)
Gearbox
Oil charge
0.75 litres (typical)
Grade of oil
SAE 40
ISO viscosity grade
150
Recommended perfluoropolyether oils
Fomblin 25/6, Krytox 1525, Drynert 25/6
2.6
Electrical data
Electrical supply
Supply voltage
200-208/380-415 V at 50 Hz, 3-phase
200-230/460 V at 60 Hz, 3-phase
Voltage tolerance
±
10% (except for 208 V and 415 V at
50 Hz, which are +6% and -10%)
Full load current ratings
See Table 2-2
Fuse types and ratings
F1 *
30 A, 600 V, Class J
F2 *
30 A, 600 V, Class J
F3 *
30 A, 600 V, Class J
F4 *
✝
20 A, 600 V, Class J
F5 *
✝
20 A, 600 V, Class J
F6 *
✝
20 A, 600 V, Class J
F7
1.6 A, 250 V
F8
1.6 A, 250 V
F9
3.15 A, 250 V
Emergency stop switch rating
24 V a.c./d.c., 5 A max
External emergency stop switch
Rating
24 V a.c., 5 A
Load
700 mA (inductive)
✝
iL 600 only
2-10
iL Dry Pumping Systems
*
These fuse ratings are included for information only. You cannot change these fuses;
a BOC Edwards service engineer must change these fuses.
Содержание iL600
Страница 18: ...iL Dry Pumping Systems 1 9 Figure 1 3 Schematic diagram of the electrical system...
Страница 21: ...1 12 iL Dry Pumping Systems Figure 1 4 Services and electrical connections on the rear of the iL system...
Страница 23: ...1 14 iL Dry Pumping Systems Figure 1 5 Electrical components shown without enclosure for clarity...
Страница 71: ...3 28 iL Dry Pumping Systems...