WARNING
101
(a) there is a fault in the Sensor Monitoring
Module PCA, or (b) a module or sensor which
should be fitted is not fitted or is disconnected,
or (c) the emergency stop button has been
pressed (or a safety sensor has operated or
your external emergency stop switch has been
operated) to shut down the iL system, or (d)
there has been a transient electrical supply
failure (longer than the hold-up time of the iL
power supply), or (e) the wrong gas module is
fitted for the current iL configuration.
WARNING
113
There is a fault in the ADC (Analogue-to-
digital convertor) in the Sensor Monitoring
Module; the ADC must be replaced.
WARNING
209
SEE MANUAL
The electrical supply voltage is too low. Check
the electrical supply and the connections to the
iL system and rectify as necessary.
WARNING
211
SEE MANUAL
The electrical supply voltage is too high.
Check the electrical supply and the
connections to the iL system and rectify as
necessary.
WARNING
309
DP CURRENT LOW
OPEN CIRCUIT
CHECK CONNECTION
The electrical current drawn by the LCDP
pump is less than normal. Check that the
electrical connections are correct and rectify as
necessary. If the electrical connections are
correct, a fuse in the Electrics and Pump
Control Module may have failed.
WARNING
311
DP CURRENT HIGH
LEAK/DEBRIS
SERVICE PUMP
The electrical current drawn by the LCDP
pump is higher than normal. There may be a
leak in the system or process debris in the
pump, or the pump motor may have failed.
Inspect the pipelines and service the pump.
WARNING
409
DP POWER LOW
OPEN CIRCUIT
CHECK CONNECTION
The electrical power consumption of the LCDP
pump is less than normal. Check that the
electrical connections are correct and rectify as
necessary. If the electrical connections are
correct, a fuse in the Electrics and Pump
Control Module may have failed.
WARNING
411
DP POWER HIGH
LEAK/DEBRIS
SERVICE PUMP
The electrical power consumption of the LCDP
pump is higher than normal. There may be a
leak in the system or process debris in the
pump, or the pump motor may have failed.
Inspect the pipelines and service the pump.
WARNING
412
LEAK/DEBRIS
SERVICE PUMP
Refer to the recommendations for error 4.11
(in this table).
iL Dry Pumping Systems
6-15
Table 6-1 - Warning messages