Warning message
Advisory message
Meaning/recommended action
WARNING
509
SEE MANUAL
The LCDP motor thermistor is short circuited.
Check the thermistor connections inside the
LCDP pump motor terminal-box and check the
connections between the LCDP pump and the
Electrics and Pump Control Module.
WARNING
611
SEE MANUAL
There is a phase imbalance in the electrical
supply to the LCDP pump. Check the
electrical supply and the connections to the iL
system. If the electrical supply and
connections are correct, the pump motor may
be faulty.
WARNING
709
MB CURRENT LOW
OPEN CIRCUIT
CHECK CONNECTION
The electrical current consumption of the
LCMB pump is lower than normal. Check that
the electrical connections are correct and
rectify as necessary. If the electrical
connections are correct, a fuse in the Electrics
and Pump Control Module may have failed.
WARNING
711
MB CURRENT HIGH
LEAK/DEBRIS
SERVICE PUMP
The electrical current consumption of the
LCMB pump is higher than normal. There
may be a leak in the system or process debris
in the pump, or the pump motor may have
failed. Inspect the pipelines and service the
pump.
WARNING
809
MB POWER LOW
OPEN CIRCUIT
CHECK CONNECTION
The electrical power consumption of the LCMB
pump is lower than normal. Check that the
electrical connections are correct and rectify as
necessary. If the electrical connections are
correct, a fuse in the Electrics and Pump
Control Module may have failed.
WARNING
811
MB POWER HIGH
LEAK/DEBRIS
SERVICE PUMP
The electrical power consumption of the LCMB
pump is higher than normal. There may be a
leak in the system or process debris in the
pump or the pump motor may have failed.
Inspect the pipelines and service the pump.
WARNING
812
MB POWER HIGH
LEAK/DEBRIS
SERVICE PUMP
Refer to the recommended actions for error
number 811 in this table.
WARNING
909
SEE MANUAL
The LCMB motor thermistor is short circuited.
Check the thermistor connections inside the
LCMB pump motor terminal-box and check
the connections between the LCMB pump and
the Electrics and Pump Control Module.
6-16
iL Dry Pumping Systems
Table 6-1 - Warning messages (continued)