SeaTrac Serial Command Interface Reference
Page 57
6.4.9.
SETTINGS_T (Settings Record Structure)
The Settings Record structure is used to either retrieve the current working settings values in
use from the beacon, or apply new changes to the beacon.
As this structure contains current calibration and communication settings for the beacon, it is
always recommended to read the contents of the structure from the beacon rather than
populating a new structure from scratch.
See Settings manipulation commands in section 7.4 from 83 for further details.
Settings marked with the “
” symbol are only applied on power-up or following a
command.
Parameter Type Description
STATUS_FLAGS UINT8
Value
containing
flags that control the generation
and output of
messages.
Bit values are…
Bits[7:3] = RESERVED
Reserved for future use, treat as 0’s.
Bits[2:0] = STATUS_MODE
Specifies how often periodic status output
messages are generated. Mask and then treat as a
value.
STATUS_OUTPUT
A bit-mask specifying which information should be
included in generated status output messages.
For each bit set in this mask, a corresponding
group of output fields will be appended to status
messages (making them larger in size).
For details of how these fields affect the status
message content, see
UART_MAIN_BAUD
Specifies the serial baud rate to be used by the
main communications port.
UART_AUX_BAUD
Reserved for future use.
When populating this field, use a default value of
BAUD_115200.
NET_MAC_ADDR
Reserved for future use.
When populating this structure, use a default value
of 0.
NET_IP_ADDR
Reserved for future use.
When populating this structure, use a default value
of 0xC0A801FA (192.168.1.250).