SeaTrac Serial Command Interface Reference
Page 35
6.3.5.
CAL_ACTION_E (Calibration Actions)
The Calibration Action enumeration defines what operation the beacon should perform when a
command is issued. Valid operations are…
Value Symbolic
Name
Summary
0x00
CAL_ACC_DEFAULTS
Sets the current accelerometer calibration
coefficient values back to defaults.
0x01
CAL_ACC_RESET
Resets the accelerometer Min and Max filtered
limit values measured by the sensor (does not
modify the current calibration).
0x02
CAL_ACC_CALC
Calculates the new accelerometer calibration
coefficients from the measured sensor limit
values.
0x03
CAL_MAG_DEFAULTS
Sets the current magnetometer calibration
values back to defaults for Hard and Sort Iron
(does not clear the magnetic buffer).
0x04
CAL_MAG_RESET
Clears the magnetic calibration buffer (does
not modify the current calibration).
0x05
CAL_MAG_CALC
Calculate and apply a new Magnetometer
calibration from current magnetic buffer
values.
0x06
CAL_PRES_OFFSET_RESET
Reset the pressure offset back to zero Bar.
0x07
CAL_PRES_OFFSET_CALC
Sets the pressure offset from the current
measured pressure, zeroing the depth sensor
reading.