Application Version = v1.0.1915
Application Checksum = 0x4DBF60E9
Pressure Sensor Id = 20905984
Pressure Sensor Type = PA
Pressure Sensor Calibrated = 2014-03-01
Pressure Sensor Min = 0.0 bar
Pressure Sensor Max = 200.0 bar
Ready...
At this point the beacon is ready to receive serial commands. Type “#0281C1” and
press return – this will send a
command requesting hardware and
firmware information.
Something similar to the following information string should be returned (if not a
formatting error message/code will be returned – see
codes)…
$0234000000011B0301690E000000000000FF900301006901B7FAC5BFFF910301007A077504
63A973BA
The fields in the above message can then be decoded using the information given in
the
command reference section of this document. Alternately, you
could use the SeaTrac Tools application to send the above command, and use the
“Journal” to decode the information fields as…
Received Len = 41 bytes (in 83 chars)
Received Data =
"$0234000000011B0301690E000000000000FF900301006901B7FAC5BFFF910301007A07750
463A973BA"
CmdId = SYS_INFO (0x02)
Uptime = 0x00000034 (52)
Section = 0x01 (1)
HardwarePartNumber = 0x031B (795)
HardwarePartRevision = 0x01 (1)
HardwareSerialNumber = 0x00000E69 (3689)
HardwareFlags = 0x00000000 (0)
BootValid = TRUE
BootPartNumber = 0x0390 (912)
BootVersionMajor = 0x01 (1)
BootVersionMinor = 0x00 (0)
BootVersionBuild = 0x0169 (361)
BootChecksum = 0xBFC5FAB7 (3217423031)
AppValid = TRUE
AppPartNumber = 0x0391 (913)
AppVersionMajor = 0x01 (1)
AppVersionMinor = 0x00 (0)
AppVersionBuild = 0x077A (1914)
AppChecksum = 0xA9630475 (2841838709)
4.4.
Fetching, Updating and Storing Settings
Using a process similar to that described in section 4.3 above, you can make you application
change the beacon settings using the following sequence of commands…