INSTALLATION MANUAL
Logic
De
fi
nition
Default
Cross out
setting
used
Optional extras
IC 1
Con
fi
guration of
command input
IC 1.
61
0
0
Input con
fi
gured as Start E.
1
Input con
fi
gured as Start I.
IC 2
Con
fi
guration of
command input
IC 2.
62
4
2
Input con
fi
gured as Open.
3
Input con
fi
gured as Close.
IC 3
Con
fi
guration of
command input
IC 3.
64
2
4
Input con
fi
gured as Ped.
5
Input con
fi
gured as Timer.
IC 4
Con
fi
guration of
command input
IC 4.
65
3
6
Input con
fi
gured as Timer Pedestrian.
1ch
Con
fi
guration
of the 1st radio
channel command
0
0
Radio control con
fi
gured as START E.
1
Radio control con
fi
gured as Start I.
2
Radio control con
fi
gured as Open.
2ch
Con
fi
guration
of the 2nd radio
channel command
9
3
Radio control con
fi
gured as Close
4
Radio control con
fi
gured as Ped
5
Radio control con
fi
gured as STOP
6
Radio control con
fi
gured as AUX0 **
3 ch
Con
fi
guration
of the 3rd radio
channel command
2
7
Not used
8
Not used
9
Radio control con
fi
gured as AUX3 **
4 ch
Con
fi
guration
of the 4th radio
channel command
5
10
Radio control con
fi
gured as EXPO1 **
11
Radio control con
fi
gured as EXPO2 **
AUX 0
Con
fi
guration of
AUX 0 output.
20-21
6
0
Output con
fi
gured as monostable Radio Channel.
1
Output con
fi
gured as SCA (gate open light).
2
Output con
fi
gured as Courtesy Light command.
3
Output con
fi
gured as Zone Light command.
4
Output con
fi
gured as Stair Light
5
Output con
fi
gured as Alarm
6
Output con
fi
gured as Flashing light
7
Output con
fi
gured as Latch
8
Output con
fi
gured as Magnetic lock
AUX 3
(Setup for
LEO B CBB DL2
3 120 F02 PHOT
USA16)
LEO B CBB DL2 3 120 F02
(
only for sw versions
7.08)
Con
fi
guration of
AUX 3 output.
26-37
0
9
Output con
fi
gured as Maintenance
10
Output con
fi
gured as Flashing Light and Maintenance.
11
Not used
12
Output con
fi
gured as Antitampering
13
Output con
fi
gured as Gate Status
14
Output con
fi
gured as Bistable Radio Channel
15
Output con
fi
gured as timed Radio Channel
FIXED CODE
Fixed code
0
0
Receiver is con
fi
gured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
1
Receiver is con
fi
gured for operation in
fi
xed-code mode.
Fixed-Code Clones are accepted.
Protection
level
Setting the
protection level
0
0
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memo-
rized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters by
repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the receiver’s
memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver’s memory.
E - The board’s parameters can be edited via the U-link network
1
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
2
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
3
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
4
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board’s parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio interference,
if any.
SERIAL MODE
Serial mode
(Identi
fi
es how
board is con
fi
gured
in a BFT network
connection).
0
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
2
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network with no
smart module (
fi
g.F)
3
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves network with no
smart module (
fi
g.F)
LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120 F02-
LEO B CBB DL2 3 120 F02 PHOT USA16
-
39
D812916 00100_02
ENGLISH