INSTALLATION MANUAL
Logic
De
fi
nition
Default
Cross out
setting
used
Optional extras
ADDRESS
Address
0
[ ___ ]
Identi
fi
es board address from 0 to 119 in a local BFT network connection.
(see U-LINK OPTIONAL MODULES section)
EXPI1
Con
fi
guration of
EXPI1 input on
input-output ex-
pansion board.
1-2
1
0
Input con
fi
gured as Start E command.
1
Input con
fi
gured as Start I command.
2
Input con
fi
gured as Open command.
3
Input con
fi
gured as Close command.
4
Input con
fi
gured as Ped command.
5
Input con
fi
gured as Timer command.
6
Input con
fi
gured as Timer Pedestrian command.
7
Input con
fi
gured as Phot (photocell) safety.
8
Input con
fi
gured as Phot op safety (photocell active during opening only).
9
Input con
fi
gured as Phot cl safety (photocell active during closing only).
10
Input con
fi
gured as Bar safety (safety edge).
11
Input con
fi
gured as safety Bar OP, safety edge with inversion active only while opening, if while closing the
movement stops.
12
Input con
fi
gured as safety Bar CL, safety edge with inversion active only while closing, if while opening the
movement stops.
13
Input con
fi
gured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is switched
automatically to safety device test input, EXPFAULT1.
14
Input con
fi
gured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/
output expansion board is switched automatically to safety device test input, EXPFAULT1
15
Input con
fi
gured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/output
expansion board is switched automatically to safety device test input, EXPFAULT1
16
Input con
fi
gured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is switched
automatically to safety device test input, EXPFAULT1.
17
Input con
fi
gured as safety Bar OP test, safety edge with inversion active only while opening, if while closing the
movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device
test input, EXPFAULT1.
18
Input con
fi
gured as safety Bar CL test, safety edge with inversion active only while closing, if while opening the
movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device
test input, EXPFAULT1.
EXPI2
Con
fi
guration of
EXPI2 input
on input-output
expansion board.
1-3
0
0
Input con
fi
gured as Start E command.
1
Input con
fi
gured as Start I command.
2
Input con
fi
gured as Open command.
3
Input con
fi
gured as Close command.
4
Input con
fi
gured as Ped command.
5
Input con
fi
gured as Timer command.
6
Input con
fi
gured as Timer Pedestrian command.
7
Input con
fi
gured as Phot (photocell) safety.
8
Input con
fi
gured as Phot op safety (photocell active during opening only).
9
Input con
fi
gured as Phot cl safety (photocell active during closing only).
10
Input con
fi
gured as Bar safety (safety edge).
11
Input con
fi
gured as safety Bar OP, safety edge with inversion active only while opening, if while closing the
movement stops.
12
Input con
fi
gured as safety Bar CL, safety edge with inversion active only while closing, if while opening the
movement stops.
EXPO1
Con
fi
guration of
EXPO2 output
on input-output
expansion board
4-5
11
0
Output con
fi
gured as monostable Radio Channel.
1
Output con
fi
gured as SCA (gate open light).
2
Output con
fi
gured as Courtesy Light command.
3
Output con
fi
gured as Zone Light command.
4
Output con
fi
gured as Stair Light.
5
Output con
fi
gured as Alarm.
EXPO2
Con
fi
guration of
EXPO2 output
on input-output
expansion board
6-7
11
6
Output con
fi
gured as Flashing light.
7
Output con
fi
gured as Latch.
8
Output con
fi
gured as Magnetic lock.
9
Output con
fi
gured as Maintenance.
10
Output con
fi
gured as Flashing Light and Maintenance.
11
Output con
fi
gured as Tra
ffi
c Light control with TLB board.
12
Output con
fi
gured as Antitampering
13
Output con
fi
gured as Gate Status
14
Output con
fi
gured as Bistable Radio Channel
15
Output con
fi
gured as timed Radio Channel
TRAFFIC LIGHT
PREFLASHING
Tra
ffi
c light
pre-
fl
ashing
0
0
Pre-
fl
ashing switched o
ff
.
1
Red lights
fl
ash, for 3 seconds, at start of operation.
TRAFFIC LIGHT
RED LAMP
ALWAYS ON
Steadily lit red
light
0
0
Red lights o
ff
when gate closed.
1
Red lights on when gate closed.
40 -