INSTALLATION MANUAL
TABLE “A”
-
PARAMETERS MENU -
(
PARA
)
Parameter
min. max.
Default
Personal
De
fi
nition
Description
OPEN WORK.T.
5
300
300
Opening operation time [s]
Maximum motor operation time, during opening.
Set the operation time so that it’s slightly longer than the complete operating
cycle time. The value is changed by the Autoset cycle, adapting it to the opera-
tion time detected
CLS WORK.T
5
300
300
Closing operation time [s]
Maximum motor operation time, during closing.
Set the operation time so that it’s slightly longer than the complete operating
cycle time. The value is changed by the Autoset cycle, adapting it to the opera-
tion time detected
TCA
0
180
40
Automatic closing time [s]
Waiting time before automatic closing.
TRF.LGHT.
CLR.T
1
180
40
Time-to-clear tra
ffi
c light
zone [s]
Time-to-clear for the zone run through by tra
ffi
c controlled by the tra
ffi
c light.
output time
1
240
10
Activation time of the
timed output [s]
Activation length of timed radio channel output in seconds
OP.DIST.SLOUD
0
99
0
(LEO B CBB DL2
3 120 F02)
(LEO B CBB
DL2 3 120
F02 PHOT
USA16)
30
(LEO B CBB DL2
3 230 L02)
Slow-down distance
during opening [%]
Slow-down distance for motor(s) during opening, given as a percentage of total travel.
The Autoset cycle changes the slow-down distance values if they don’t allow at
least 50cm of travel at slowed speed.
W A R N I N G : O n c e t h e p a r a m e t e r h a s b e e n e d i t e d , a
complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
CL.DIST.SLOUD
0
99
0
(LEO B CBB DL2
3 120 F02)
(LEO B CBB DL2
3 120 F02 PHOT
USA16)
30
(LEO B CBB DL2
3 230 L02)
Slow-down distance
during closing [%]
Slow-down distance for motor(s) during closing, given as a percentage of total
travel. The Autoset cycle changes the slow-down distance values if they don’t
allow at least 50cm of travel at slowed speed.
WARNING: Once the parameter
has been edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads “SET”, obstacle detection is not active.
PARTIAL
OPENING
10
50
20
Partial opening [%]
Partial opening distance as a percentage of total opening following activation
of PED pedestrian command.
OP.FORCE
1
99
75
Leaf force during
opening [%]
Force exerted by leaf/leaves during opening.
[if encoder = 0 or 1] the set force value represents the network voltage % that is
supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force stored
during the autoset cycle (and subsequently updated), before an obstacle alarm
is generated.
The parameter is set automatically by the autoset function.
WARNING: It a
ff
ects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
CLS.FORCE
1
99
75
Leaf force during closing
[%]
Force exerted by leaf/leaves during closing.
[if encoder = 0 or 1] the set force value represents the network voltage % that is
supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force stored
during the autoset cycle (and subsequently updated), before an obstacle alarm
is generated.
The parameter is set automatically by the autoset function.
WARNING: It a
ff
ects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
OP.SLWD.FORCE
1
99
75
Leaf/leaves force during
opening during
slow-down
“Force exerted by leaf/leaves during opening at slow-down speed.”
[if encoder = 0 or 1] the set force value represents the network voltage % that is
supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force
stored during the autoset cycle (and subsequently updated), before an obstacle
alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It a
ff
ects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
CLS.SLWD.
FORCE
1
99
75
Leaf/leaves force during
closing during
slow-down [%]
“Force exerted by leaf/leaves during closing at slow-down speed. “
[if encoder = 0 or 1] the set force value represents the network voltage % that is
supplied by the board to the motor during the movement.
[if encoder = 2] This is the percentage of force delivered, beyond the force
stored during the autoset cycle (and subsequently updated), before an obstacle
alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It a
ff
ects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary (**).
BRAKE
0
99
0
Braking [%]
Percentage of braking applied to stop motion of motor(s).
Maintenance
0
250
0
Programming number of
operations for
maintenance threshold
[in hundreds]
Allows you to set a number of operations after which the need for maintenance
will be reported on the AUX output con
fi
gured as Maintenance or Flashing
Light and Maintenance .
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) Impact forces can be reduced by using deformable edges.
TABLE “B”
-
LOGICS
(
LOGIC
)
Logic
De
fi
nition
Default
Cross out
setting
used
Optional extras
TCA
Automatic Closing
Time
0
0
Logic not enabled
1
Switches automatic closing on
FAST CLS.
Fast closing
0
0
Logic not enabled
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120 F02-
LEO B CBB DL2 3 120 F02 PHOT USA16
-
37
D812916 00100_02
ENGLISH