Programming
Bennett HF H35 Instruction Manual
46
PROCEDURE
1.
Press the number
1
and
1
, then the
[MODE]
button on the keypad. The
PPM display shows the dispenser is in Menu Code 11. If the dispenser
has not been programmed since it came from the factory, the number
0.999 appears in the main display. This is the default setting.
2.
To change the setting, use the
0
through
9
buttons on the keypad to
enter a new mass allocation limit.
Note:
If an error is made, press the
0
button until the PPM display shows all zeros. Enter a new number.
a.
Example
: If a mass allocation of 0050 has been set, the
dispenser stops the flow of fuel at 50 mass units.
3.
When the correct mass allocation appears in the main display, press the
[
ENTER
] button to save the selection.
4.
Press the [
CANCEL
] button to exit this Menu Code.
Figure 4.27
–
Mass Allocation Limit
MENU CODE 12 - PROGRAM THE LAST SALE AND IDLE TIMER
PROCEDURE
–
SETTING LAST SALE TIMEOUT
The
Last Sale Timeout
is the amount of time that the last sale is shown on the main display before the dispenser returns to the
idle state. The default timeout is 30 seconds, and the maximum timeout is 99 seconds.
1.
Press the number
1
and
2
, then the [
MODE
] button on the keypad. The
PPM display shows the dispenser is in Menu Code 12. If the dispenser
has not been programmed since it came from the factory, the number
30 appears in the main display. This is the default setting.
2.
To change the setting, use the
0
through
9
buttons on the keypad to
enter a value in seconds.
Note
: If an error is made, press the correct
number. The new number replaces the error.
3.
Press the [
ENTER
] button to save the new setting and to cycle to the
next option.
4.
If programming is complete press, [
CANCEL
] to exit this Menu Code.
Figure 4.28
–
Last Sale Timeout
PROCEDURE
–
SETTING IDLE TIMEOUT
Idle Timeout
is a programmable feature can be enabled when any activity (the handle is lifted, pressing a button, etc.) is detected
at the dispenser from an idle state or if there is no activity at the dispenser detected for the time equal to the idle timeout the
dispenser will return to its idle state.
Chapter 1
To change the setting, use the
0
through
9
buttons on the keypad
to enter a value in seconds. If the dispenser has not been programmed since
it came from the factory, the number 15 appears in the main display. This is
the default setting.
Chapter 2
Press the [
ENTER
] button to save the new setting.
Chapter 3
Press the [
CANCEL
] button to exit this Menu Code.
Chapter 4
If this is a two-sided dispenser, changing one side will
automatically change the second side to the same value as the first.
Figure 4.29
–
Idle Timeout
Sale $
A l l O C
Kilograms
0 9 9 9
C O d E
1 1
Sale $
L A S T
Kilograms
S A L E 3 0
C O d E
1 2
Sale $
i d L E
Kilograms
1 5
C O d E
1 2
Содержание HIGH FLOW H35
Страница 12: ...Product Introduction Bennett HF H35 Instruction Manual 8 DISPENSER IDENTIFICATION NUMBER DIN...
Страница 84: ...Schematics Bennett HF H35 Instruction Manual 80 CHAPTER 8 SCHEMATICS...
Страница 85: ...Schematics Bennett HF H35 Instruction Manual 81...
Страница 86: ...Schematics Bennett HF H35 Instruction Manual 82...
Страница 87: ...Schematics Bennett HF H35 Instruction Manual 83...
Страница 88: ...Schematics Bennett HF H35 Instruction Manual 84...
Страница 89: ...Schematics Bennett HF H35 Instruction Manual 85...
Страница 90: ...Schematics Bennett HF H35 Instruction Manual 86...
Страница 91: ...Schematics Bennett HF H35 Instruction Manual 87...
Страница 92: ...Schematics Bennett HF H35 Instruction Manual 88...
Страница 93: ...Schematics Bennett HF H35 Instruction Manual 89...
Страница 94: ...Schematics Bennett HF H35 Instruction Manual 90...
Страница 95: ...Schematics Bennett HF H35 Instruction Manual 91...
Страница 96: ...Schematics Bennett HF H35 Instruction Manual 92...
Страница 97: ...Schematics Bennett HF H35 Instruction Manual 93...
Страница 98: ...Schematics Bennett HF H35 Instruction Manual 94...