INSTALLATION OF BREAKAWAYS, HOSES, AND NOZZLES
DANGER: FAILURE TO FOLLOW OEM INSTALLATION INSTRUCTIONS AND MAINTENANCE COULD RESULT IN A GAS LEAKAGE,
FIRE, OR AN EXPLOSION THAT COULD CAUSE DEATH, PERSONAL INJURY, AND DAMAGE OF PROPERTY.
WARNING: IMPROPER MAINTENANCE CAN CAUSE INJURY OR DAMAGE EQUIPMENT THAT CAN AFFECT BENNETT PACIFIC
SERIES HYDROGEN DISPENSER PERFORMANCE.
CAUTION: Bennett Limited Warranty for Pacific Series Hydrogen Dispensers Installed in the United States excludes hanging
hardware, nozzles, hoses, fittings, and hose retractors. Please send all warranty claims to the original manufacturer. Please
contact Bennett Customer Service Department at 231-719-6050 for questions.
CAUTION: Perform all preventative and schedule maintenance checks as recommended by the original manufacturer for all
NON-Bennett components.
All component installations, maintenance, and service must be performed by a technician who is trained in accordance with all codes,
standards, and regulations.
Note:
Installation instructions and specifications may vary per manufacturer. Refer to the original equipment
manufacturer (OEM) for detailed information.
•
Breakaway devices must be in accordance with
HGV4.4, Standard for Breakaway Devices for Hydrogen Gas Dispensing Hoses and
Systems
and used between approved nozzles, hoses, and the dispenser frame.
•
Hoses must meet
CSA Requirements for Hose and Hose Assemblies for Compressed Hydrogen Dispensing Systems, HGV 4.2.
•
Hoses must be protected from any contact with the ground and automobiles. Hoses must
NOT
contain any sharp bends, punctures,
slices, scrapes, etc.
•
Hoses must be periodically inspected for damage and must be replaced if damaged. Follow all maintenance guidelines per
manufacturer’s instructions.
•
Nozzles must comply with
SAE J2600 - Standard for Compressed Hydrogen Surface Vehicle Refueling Connection Devices
.
WIRING INSTRUCTIONS
GENERAL WIRING INSTRUCTIONS
WARNING: THESE NOTES ARE “MUST DO” REQUIREMENTS TO ENSURE A SUCCESSFUL INSTALLATION THAT MEETS BENNETT’S
LIMITED WARRANTY REQUIREMENTS.
1.
Electrical wiring and equipment must be in accordance with Article 500 of NFPA Code 70 and Class 1, Division 2, Group B (hydrogen),
NFPA Code 2 Hydrogen Technologies Code, state, and local electrical codes.
2.
Check with Federal, State, and Local Codes for conduit use in your area. Bennett recommends rigid metal conduit.
3.
Do not use PVC conduit. Use only Rigid metal conduit.
4.
All wiring gauges is minimum required, stranded wire with THHN insulation must be used. Do NOT use wire smaller than listed on the
Bennett wiring diagrams. For long runs increase wire size accordingly.
5.
Do not reuse old wire from an existing installation.
6.
Do not use wire nuts on data communication wires. Do not splice data communication wires they must be direct runs.
7.
Do not use wire nuts on ground circuits, use only compression type connectors.
8.
The wire separator (supplied with the pump) must be installed on the wires as they exit the pump conduit before the wires are
terminated to the 819 Power Board. The wire separator is needed to properly seal the conduit in the last step of installation.
9.
Electronic power must be on a dedicated circuit breaker. The dispenser is factory wired to accept AC voltages ranging from 100 to 250
volts AC for its operation.
10.
Electronic power for all dispensers at the installation must be wired to the same AC line phase or damage will result to the dispensers.
This will avoid a cross phase condition on the remote relay control wires.
11.
Use 15 AMP neutral breaking circuit breakers, which are supplied by the customer. The maximum distance from the breaker panel to
the dispenser is 500 feet (150m).
Содержание HIGH FLOW H35
Страница 12: ...Product Introduction Bennett HF H35 Instruction Manual 8 DISPENSER IDENTIFICATION NUMBER DIN...
Страница 84: ...Schematics Bennett HF H35 Instruction Manual 80 CHAPTER 8 SCHEMATICS...
Страница 85: ...Schematics Bennett HF H35 Instruction Manual 81...
Страница 86: ...Schematics Bennett HF H35 Instruction Manual 82...
Страница 87: ...Schematics Bennett HF H35 Instruction Manual 83...
Страница 88: ...Schematics Bennett HF H35 Instruction Manual 84...
Страница 89: ...Schematics Bennett HF H35 Instruction Manual 85...
Страница 90: ...Schematics Bennett HF H35 Instruction Manual 86...
Страница 91: ...Schematics Bennett HF H35 Instruction Manual 87...
Страница 92: ...Schematics Bennett HF H35 Instruction Manual 88...
Страница 93: ...Schematics Bennett HF H35 Instruction Manual 89...
Страница 94: ...Schematics Bennett HF H35 Instruction Manual 90...
Страница 95: ...Schematics Bennett HF H35 Instruction Manual 91...
Страница 96: ...Schematics Bennett HF H35 Instruction Manual 92...
Страница 97: ...Schematics Bennett HF H35 Instruction Manual 93...
Страница 98: ...Schematics Bennett HF H35 Instruction Manual 94...