Programming
Bennett HF H35 Instruction Manual
43
NUMBER OF SIDES
This option is used to set the number of sides on the dispenser. The default
setting for a Two-Sided Dispenser is
2
.
1 = 1 Side
2 = 2 Sides (Default)
Once
Enter
has been pressed from the previous option, the number of sides
appear in the main display. The default setting for
SIDES
is set as 2.
If necessary, enter the recommended default value for a one-sided dispenser
(1) or a two-sided dispenser (2).
Press
Enter
to save setting and to advance to the next option. If programming
is complete, press the
Cancel
button to exit this menu code.
Figure 4.18 - Sides Configuration
NUMBER OF GRADES
This option is used to select the number of grades that is used per side. The
default setting is 1-grade.
1 = 1 Grade (Default)
2 = 2 Grades
Once
Enter
has been pressed from the previous option, the number of grades
will appear in the main display. The default setting is
1
-
Grade
.
To change the setting, press the
1
or
2
button on the keypad.
Note
: If an error
is made, press the correct number. The new number replaces the error.
Press [
ENTER
] to save the new setting and to advance to the next option. If
programming is complete, press [
CANCEL]
to exit this menu code.
Figure 4.19
–
Grades Configuration
NUMBER OF HOSES
This option is used to select the number of hose’s used per side. The default
setting is 1-hose.
1 = 1 Hose (Default)
2 = 2 Hoses
Once
Enter
has been pressed from the previous option, the number of hoses
will appear in the main display.
To change the setting, press the
1
or
2
button on the keypad.
Note
: If an error
is made, press the correct number. The new number replaces the error.
Press [
ENTER
] to save the new setting and to advance to the next option. If
programming is complete, press [
CANCEL]
to exit this menu code.
Figure 4.20
–
Number of Hoses Configuration
NUMBER OF TIERS
This option is used to select the number of tiers used. This option is set at the
factory. The default setting will appear in the Main Display.
Note:
Hydrogen
should be set to tier 1 only.
•
1 = 1 Tier (Default)
•
2 = 2 Tier
1.
Once
Enter
has been pressed from the previous option, the number of
tiers will appear in the main display.
2.
The default setting is for 1-Tier.
Note:
Hydrogen should be set to tier 1
only.
3.
If necessary, enter the recommended default setting for
number of tiers
using the numeric keypad. This option will only accept the options listed
Figure 4.21
–
Number of Tiers Configuration
Sale $
S i d E s
Kilograms
2
C O d E
7
Sale $
G R A d E s
Kilograms
1
C O d E
7
Sale $
H O s e s
Kilograms
1
C O d E
7
Sale $
T I E R
Kilograms
1
C O d E
7
Содержание HIGH FLOW H35
Страница 12: ...Product Introduction Bennett HF H35 Instruction Manual 8 DISPENSER IDENTIFICATION NUMBER DIN...
Страница 84: ...Schematics Bennett HF H35 Instruction Manual 80 CHAPTER 8 SCHEMATICS...
Страница 85: ...Schematics Bennett HF H35 Instruction Manual 81...
Страница 86: ...Schematics Bennett HF H35 Instruction Manual 82...
Страница 87: ...Schematics Bennett HF H35 Instruction Manual 83...
Страница 88: ...Schematics Bennett HF H35 Instruction Manual 84...
Страница 89: ...Schematics Bennett HF H35 Instruction Manual 85...
Страница 90: ...Schematics Bennett HF H35 Instruction Manual 86...
Страница 91: ...Schematics Bennett HF H35 Instruction Manual 87...
Страница 92: ...Schematics Bennett HF H35 Instruction Manual 88...
Страница 93: ...Schematics Bennett HF H35 Instruction Manual 89...
Страница 94: ...Schematics Bennett HF H35 Instruction Manual 90...
Страница 95: ...Schematics Bennett HF H35 Instruction Manual 91...
Страница 96: ...Schematics Bennett HF H35 Instruction Manual 92...
Страница 97: ...Schematics Bennett HF H35 Instruction Manual 93...
Страница 98: ...Schematics Bennett HF H35 Instruction Manual 94...