![Beckman Coulter Avanti J-25 Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/beckman-coulter/avanti-j-25/avanti-j-25_instruction-manual_2719702070.webp)
4-10
Troubleshooting
To replace the panel on the centrifuge,
Action
Result
1. Holding the panel at the top
(with the instrument label
facing out), insert the three
grooved brackets on the
bottom inside of the door
over the front panel retaining
strip (see Figure 4-4). Push
the top of the front panel
into place.
Figure 4-4. Front Panel Retaining Strip
2. Hold the left top edge in
place and insert the allen
wrench through the hole.
Turn to the right (clockwise)
about one-half turn, until
you reach a stop.
The first latch engages.
3. Repeat step 2 on the
right side.
The second latch engages.
JCF-Z ROTOR IDENTIFICATION
The rotor identification system can, under two specific conditions,
misidentify the JCF-Z continuous flow/zonal rotor. Misidentification
has occurred if a rotor name other than JCF-Z appears in the ROTOR
display during the run, when rotor identification is complete. If the
rotor is misidentified, stop the run and follow one of the steps below.
Retaining
Strip