PARAMETER
RANGE
OF
VALUES
DEFAULT
VALUE
FUNCTION
Angle
4
Ø° - 89°
Ø°
Rotates a pattern counterclock-
wise, in 1° increments.
Origin
5
ON/OFF
ON
When On, automatically returns
the pantograph to the pattern ori-
gin, when sewing has been com-
pleted.
Socks
6
Ø-3
Ø
Used for the sock frame attach-
ment, automatically programs two
repetitions of a pattern, letting you
set up spacing between each pat-
tern for the frame that will be
used. Ø = Off
1 = On - Normal setup
2 = On - second repetition mir-
rored
3 = On - second repetition rotated
180°
When Socks is on, Origin (# 5) is
automatically turned off, so the
machine can alternate between
two origin points. See the Me-
chanical Guide for instructions.
Appliqué
7
ON/OFF
OFF
Moves the pantograph forward for
easy placement of appliqué fabric.
The default movement is 1-1/2
times the height of the pattern. A
new value can be programmed in
the A. Offset parameter.
A. Offset
8
-999mm to
300mm
Ømm
Sets the amount the pantograph
will move when Appliqué is on. If
set at Ø, the pantograph moves
1-1/2 times the height of the pat-
tern.
2-16 Memory Operations
BENS Operation Guide - 12/99
Содержание BENS
Страница 1: ......
Страница 6: ...Chapter 1 Overview BENS Operation Guide 12 99 Overview 1 1...
Страница 21: ...Menu Overview 1 16 Overview BENS Operation Guide 12 99...
Страница 32: ...Chapter 2 Memory Operations BENS Operation Guide 12 99 Memory Operations 2 1...
Страница 64: ...Chapter 3 Sewing BENS Operation Guide 12 99 Sewing 3 1...
Страница 91: ...Chapter 4 Error Codes BENS Operation Guide 12 99 Error Codes 4 1...