11
SECTION 2 INSTALLATION
Positioning of the machine will normally be determined by site staff, however when installing
the machine check the following conditions and if any one of them is likely to cause problems
with machine operation they should be brought to the attention of the site staff and an
alternate site suggested:
•
The machine should be standing on a level, flat and stable floor
•
Ensure there are no local sources of high temperatures such as fires or radiators
•
Try to avoid nylon carpets to minimise problems with static
•
Ensure there are no local sources or high levels of moisture
•
Check that the mains supply socket is rated for 13 Amps and fitted with an on / off switch
and is sited nearby to avoid a long mains lead. Check that the supply socket is in good
condition and not showing any signs of overheating or damage.
•
Check that the mains socket is fitted with an earth connection and that the earth is
correctly connected
•
Machines look best in subdued lighting
•
The machine should be positioned where site staff can supervise it.
When the machine is positioned check that it is stable and does not rock. Check that the
mains cable is undamaged and that the mains plug is fitted with a 5A fuse. Connect the
mains lead to the mains socket at the rear of the machine and to the site supply socket.
The machine requires a nominal supply of 230 V AC, 50 Hz but should easily tolerate a
variation of plus or minus 10% (207 to 253 volts).
2.1 Mains supply requirements
Connection to the mains supply is through an I.E.C. Europlug at the rear of the machine.
The supply should be protected by a 3 Amp fuse. In most installations this is achieved by
fitting a 3 Amp fuse to the plug at the remote end of the mains supply cable. A good earth is
necessary if safety is to be assured and problems from static electricity are to be avoided.
The machine requires a nominal supply of 230V AC +/- 10%.
Connect the mains lead to the mains socket at the rear of the machine and to the site supply
socket.
2.2 Initialisation
Whenever the mains power to the machine is switched on with the doors closed a number of
automatic resetting and self-checking procedures take place. The machine identity is shown
on the MPU6 and machines alphanumeric display. If any door is open the machine identity,
software version number and the software options set are displayed.
With both doors closed, after a short delay the reels spin forwards one revolution to position
one then backwards one revolution to position one, to check the reel opto inputs, then they
spin to the last game position. This is necessary for the MPU6 to determine the current reel
positions.
Finally the machine enters “attract” mode, the coin mech and where fitted the note acceptor
is enabled and the machine becomes operational.
Содержание MPU6