24
english
7
Specific functions BML SL1 (continued)
7.2.2 Preset function
The Preset function (“null position”) can be used to set the
start (null) position for the BML absolute magnetic encoder
system. Any desired values can be set in the input field.
The output value of the BML (in increments) after the
Preset function can be calculated with the following
equation:
BML output [inc] =
Preset [µm]
BML resolution [μm/inc]
The Preset function changes some BML parameters. Do
not remove the sensor head during this procedure.
7.2.3 Real time errors
The real time errors are displayed with the help of LEDs:
Real time errors
Possible cause
Troubleshooting
Amplitude error
The working range of the
sensor head has been
exceeded or the magnetic
tape is defective.
►
Check orientation of the tape (alignment of sensor head
with magnetic tape).
►
Exchange the magnetic tape.
System error
Sensor head defective.
►
Check supply voltage.
►
Check temperature.
►
Replace sensor head.
Inconsistency
Plausibility check for the
sensor head fails.
►
Check orientation of the tape (alignment of sensor head
with magnetic tape).
►
Exchange the magnetic tape.
Signal quality too low
The working range of the
sensor head has been
exceeded or the magnetic
tape is defective.
Tab. 7-2: Real time errors
BAE PD-ML-010-04
Configuration Tool + USB-Adapter
Содержание BAE PD-ML-010-04
Страница 1: ...deutsch Configuration Tool USB Adapter english Configuration Tool USB Adapter BAE PD ML 010 04...
Страница 2: ...www balluff com...
Страница 3: ...BAE PD ML 010 04 Configuration Tool USB Adapter deutsch...
Страница 4: ...www balluff com...
Страница 39: ...BAE PD ML 010 04 Configuration Tool USB Adapter english...
Страница 40: ...www balluff com...
Страница 75: ......