www.balluff.com
29
english
8
Specific functions of BML BM1/BM2 (continued)
Settings
Fig. 8-3: Set calibration range and speed
Fig. 8-4: Set measuring time
Depending on the selected application type, different
settings are available before calibration (see Tab. 8-2).
Application
type
Settings
Options
Note
Rotative (axial)
Calibrating range
Full (360°)
Entire measuring range (360°) is calibrated.
By segment (less than 360°)
Measuring range less than 360° is calibrated.
Rotation speed
Multiple selection options
Specifies the speed range with which the
calibration is performed.
Measuring time [s] 5…30
Specifies the time frame in seconds that is
sufficient to move from the start position to the
end position during segment calibration.
Rotative (radial) /
linear
Measuring time [s] 5…30
Specifies the time frame in seconds that is
sufficient to move from the start position to the
end position during linear calibration.
Tab. 8-2: Settings of BML BM1/BM2
The application types
Rotative (axial)
or
Rotative
(radial) / linear
can be changed in the system
parameters (see chapter 8.1.1 on page 26).
The recommended rotational speed for
optimized calibration is between 100 and
300 rpm.
By clicking the
n
eXt
button, the next step
C
aLiBratiOn
appears.
BAE PD-ML-010-04
Configuration Tool + USB-Adapter
Содержание BAE PD-ML-010-04
Страница 1: ...deutsch Configuration Tool USB Adapter english Configuration Tool USB Adapter BAE PD ML 010 04...
Страница 2: ...www balluff com...
Страница 3: ...BAE PD ML 010 04 Configuration Tool USB Adapter deutsch...
Страница 4: ...www balluff com...
Страница 39: ...BAE PD ML 010 04 Configuration Tool USB Adapter english...
Страница 40: ...www balluff com...
Страница 75: ......