Page 14
Installation:
Step-by Step Procedure
24
Place the console Power Adapter (model 3120-
036) beneath the counter and plug into the con-
sole. Console power switch should be “OFF”. Leave
the multipin connector detached from the console.
25
Plug the console Power Adapter (model 3120-
036) into an un-interruptable power supply
(UPS) with an 80 watt, 110 VAC rating. Plug the UPS
into a 110 VAC wall receptacle.
26
If the optional Ticket Printer (model 3120-035)
has been purchased, connect the printer power
cord to the same UPS electric power source. Connect
the communication cable of the printer to the “PTR”
port on the back side of the console. Load the printer
paper spool, per instructions in the printer box. Then
turn “OFF” printer power switch.
27
If the Host PC Interface (model 3120-035) has
been purchased, connect the PC cable between
the console and the serial port on the PC, per the
instruction in the Interface Kit.
28
In the pump room, determine the amount of fl uid
in each tank. Record tank fl uid quantities on the
“SYSTEM PLANNING WORKSHEET”,
[Figure 17,
page 9]
. Other parts of the worksheet should already
be completed by the factory to accompany your
Spectrum shipment.
18
For each dispense point, run one length of
Solenoid Cable (model 3123-xxx) from the Fluid
Solenoid Valve to its associated Smart Controller.
Refer to the “SYSTEM PLANNING WORKSHEET”
to assure correct cable run placement. Secure the
cable at suitable locations with cable ties. Refer to
“WIRING DETAIL, FLUID SOLENOID VALVES”,
[Figure 29, page 21]
.
19
On each Solenoid Valve Cable, strip and mount
the Smart Controller
TM
wire ends to the desig-
nated Smart Controller
TM
ports using the jeweler’s
screwdriver. Strip the wire ends per “WIRE END
DETAIL”,
[Figure 27, page 21]
. Refer also to “WIRING
DETAIL, SMART CONTROLLERS”,
[Figure 26,
page 20]
. Attach wires at the valve end using crimp
connectors or screw caps. Be sure to include Ready
Light wires in the valve-end connections, as shown in
the “WIRING DETAIL, FLUID SOLENOID VALVES”,
[Figure 29, page 21]
.
20
Run one Comm/Power Cable (model 3121-xxx)
between each of the Smart Controllers
TM
, begin-
ning with the controller nearest the parts counter and
ending with the controller most distant from the parts
counter. Run cables in a single chain (no branch-
ing).Strip per “WIRE END DETAIL”,
[Figure 27, page
21]
and attach wire ends to the designated terminal
plugs on the Smart Controllers
TM
using the jeweler’s
screwdriver. Refer to “WIRING DETAIL, SMART
CONTROLLER”,
[Figure 26, page 20]
. Secure cables
using wire ties.
21
Run one Comm/Power Cable (model 3121-xxx)
from the Smart Controller
TM
nearest the parts
counter to the Spectrum Queuing Console
TM
. Secure
cable using wire ties.
22
Install a tail-end resistor (one is furnished with
each Smart Controller) across the OUT (+) and
OUT (-) terminals on the Air Smart Controller in the
pump room and on the farthest Fluid Smart Control-
ler in the service bays. Refer to “Wiring Detail, Smart
Controller”,
[Figure 26, page 20]
.
Queuing Console Installation
23
At the parts counter, terminate the console end of
the Comm/Power Cable (model 3121-xxx) from
the service bays. Attach wire ends at the designated
terminal points on the extension cable terminal strip.
Use a fl at screwdriver blade to push the terminal open-
ing buttons. Refer to “WIRING DETAIL, CONSOLE”,
[Figure 25, page 19]
.
!
Use gentle movement to remove or
install the multipin connector in the
console. Heavy force could damage the
connector or its mating part.
CAUTION
For improved operating reliability,
it is highly recommended that the
console power adapter and ticket printer
power plug be installed through an un-
interruptable power supply (UPS) with
an 80 watt rating.
NOTE