Chapter 6. Communication
82
AquaTrans™ AT600 User’s manual
D90
D90
3472
User
Digital out 2 alarm measurement type
RW
INT32
D92
3474
User
Digital out 2 alarm test value
RW
INT32
D94
3476
User
Digital out 2 alarm state
RW
INT32
D96
3478
User
Digital out 2 alarm type
RW
INT32
E00
E00
3584
RO
Analog out measurement value
RO
(IEEE 32 bit)
E02
3586
RO
Digital out 1 pulse measurement value
RO
(IEEE 32 bit)
E04
3588
RO
Digital out 1 frequency measurement value
RO
(IEEE 32 bit)
E06
3590
RO
Digital out 1 alarm measurement value
RO
(IEEE 32 bit)
E08
3592
RO
Digital out 2 pulse measurement value
RO
(IEEE 32 bit)
E0A
3594
RO
Digital out 2 frequency measurement value
RO
(IEEE 32 bit)
E0C
3596
RO
Digital out 2 alarm measurement value
RO
(IEEE 32 bit)
1100
1100
4352
Viewer
HART meter address
RW
INT32
1102
4354
Viewer
HART preamble length
RW
INT32
1104
4356
Viewer
HART device ID
RW
INT32
1106
4358
Viewer
HART assembly number
RW
INT32
1140
1140
4416
Viewer
HART dynamic variable index_1
RW
INT32
1142
4418
Viewer
HART dynamic variable index_2
RW
INT32
1144
4420
Viewer
HART dynamic variable index_3
RW
INT32
1146
4422
Viewer
HART dynamic variable index_4
RW
INT32
1300
1300
4864
RO
HART configuration change count
RO
INT32
1302
4866
RO
HART device status
RO
INT32
1304
4868
RO
HART device status extended
RO
INT32
1306
4870
RO
HART master status
RO
INT32
1308
4872
RO
HART secondary status
RO
INT32
130A
4874
RO
HART variable status
RO
INT32
1500
1500
5376
User
PC MODBUS baud rate
RW
INT32
1502
5378
User
PC MODBUS parity
RW
INT32
1504
5380
User
PC MODBUS stop bits
RW
INT32
1506
5382
User
PC MODBUS meter address
RW
INT32
1540
1540
5440
User
Log control/status
RW
INT32
1542
5442
User
Log interval
RW
INT32
1544
5444
User
Logging time
RW
INT32
1546
5446
User
Number of variables to log
RW
INT32
1580
1580
5504
User
Variable address array
RW
INT32
15C0
15C0
5568
User
Variable unit code array
RW
INT32
1700
1700
5888
RO
PC service baud rate
RO
INT32
1702
5890
RO
PC service parity
RO
INT32
1704
5892
RO
PC service stop bits
RO
INT32
1706
5894
RO
PC service meter address
RO
INT32
1740
1740
5952
RO
Number of records
RO
INT32
Register
(in hex)
Register
(in decimal)
Access
level
Description
RO/RW Format
Содержание Panametrics AquaTrans AT600
Страница 1: ...panametrics com BH001C11 Rev F AquaTrans AT600 User s manual...
Страница 2: ......
Страница 4: ...ii no content intended for this page...
Страница 10: ...Contents viii AquaTrans AT600 User s manual no content intended for this page...
Страница 20: ...Chapter 1 General installation instructions 10 AquaTrans AT600 User s manual no content intended for this page...
Страница 36: ...Chapter 3 Wiring the AT600 electronics 26 AquaTrans AT600 User s manual no content intended for this page...
Страница 84: ...Chapter 4 Initial setup and programming 74 AquaTrans AT600 User s manual no content intended for this page...
Страница 150: ...Chapter 6 Communication 140 AquaTrans AT600 User s manual no content intended for this page...
Страница 158: ...Appendix B Specifications 148 AquaTrans AT600 User s Manual no content intended for this page...
Страница 162: ...Appendix C Specifications 152 AquaTrans AT600 User s Manual no content intended for this page...
Страница 164: ...Appendix D Menu maps 154 AquaTrans AT600 User s Manual D 2 The main menu Figure 42 The main menu...
Страница 172: ...Warranty 162 AquaTrans AT600 User s Manual...
Страница 173: ......