INTRODUCTION
•
1
Chapter 1
Chapter 1
INTRODUCTION
The Axopatch 200B is an improved and enhanced version of the Axopatch 200A amplifier
that ushered in a new generation of patch-clamp amplifiers. It offers unsurpassed
performance intight-seal patch clamp for single-channel and whole-cell voltage and current
clamping. Its noise in single-channel recording is the lowest of any available patch clamp;
its series-resistance compensation in whole-cell mode is the most effective of any existing
patch clamp, and it includes series resistance compensation in current clamp. Three
headstage settings offer an extremely wide range of recording capability, from single-
channel to loose patch to whole-cell. In addition, it includes built-in support for
capacitance and voltammetric measurements, and a novel slim headstage design that allows
easy pipette access to the experimental preparation.
The Axopatch 200B achieves its ultra-low noise performance by cooling components of the
innovative capacitive feedback circuitry used for single-channel recording. This
technology was developed by Axon Instruments engineers over a period of several years,
with extensive design and test contributions from scientific consultants.
The capacitive feedback technique is complicated. The headstage output has to be
periodically reset every time the voltage across the capacitor increases towards the limits of
the power supply of the instrument. Much of the circuitry of the Axopatch 200B is devoted
to eliminating the transients introduced by these resets. In most circumstances, the
transient elimination is so good that the resets will not affect the recording and the benefits
of the capacitor feedback will be available without penalty.
For whole-cell recording, the noise benefits of the capacitive feedback technique are
swamped by the noise sources of the electrode and the membrane capacitance. Since the
noise benefits cannot be realized, and at the same time the frequency of resets is high
Содержание Axopatch 200B
Страница 2: ......
Страница 8: ...INFORMACION IMPORTANTE Axopatch 200B Copyright March 1997 1999 Axon Instruments Inc ...
Страница 26: ......
Страница 56: ......
Страница 86: ......
Страница 118: ......
Страница 134: ......
Страница 136: ......
Страница 146: ......
Страница 148: ......
Страница 150: ......
Страница 152: ......
Страница 153: ...Circuit Diagrams Request Form ...