User's Manual
604
Document #: LTRT-65432
MP-11x & MP-124
Parameter
Description
Web: Disconnect on Broken Connection
EMS: Disconnect Calls on Broken
Connection
[DisconnectOnBrokenConnection]
Determines whether the device releases the call if RTP
packets are not received within a user-defined timeout.
[0]
No
[1]
Yes (default)
Notes:
The timeout is configured by the
BrokenConnectionEventTimeout parameter.
This feature is applicable only if the RTP session is
used without Silence Compression. If Silence
Compression is enabled, the device doesn't detect a
broken RTP connection.
During a call, if the source IP address (from where the
RTP packets are received) is changed without notifying
the device, the device filters these RTP packets. To
overcome this, set the DisconnectOnBrokenConnection
parameter to 0; the device doesn't detect RTP packets
arriving from the original source IP address and
switches (after 300 msec) to the RTP packets arriving
from the new source IP address.
This parameter can also be configured in an IP Profile.
Web: Broken Connection Timeout
EMS: Broken Connection Event
Timeout
[BrokenConnectionEventTimeout]
Defines the time period (in 100-msec units) after which a
call is disconnected if an RTP packet is not received.
The valid range is from 3 (i.e., 300 msec) to an unlimited
value (e.g., 20 hours). The default is 100 (i.e., 10000 msec
or 10 seconds).
Notes:
This parameter is applicable only if the parameter
DisconnectOnBrokenConnection is set to 1.
Currently, this feature functions only if Silence
Suppression is disabled.
Web: Disconnect Call on Silence
Detection
EMS: Disconnect On Detection Of
Silence
[EnableSilenceDisconnect]
Determines whether calls are disconnected after detection
of silence.
[1]
Yes = The device disconnects calls in which silence
occurs (in both call directions) for more than a user-
defined time.
[0]
No = (Default) Call is not disconnected when silence
is detected.
The silence duration can be configured by the
FarEndDisconnectSilencePeriod parameter (default 120).
Note:
To activate this feature, set the parameters
EnableSilenceCompression and
FarEndDisconnectSilenceMethod to 1.
Web: Silence Detection Period
[sec]
EMS: Silence Detection Time Out
[FarEndDisconnectSilencePeriod]
Defines the duration of the silence period (in seconds) after
which the call is disconnected.
The range is 10 to 28,800 (i.e., 8 hours). The default is 120
seconds.
Note:
For this parameter to take effect, a device reset is
required.
Web: Silence Detection Method
[FarEndDisconnectSilenceMethod]
Determines the silence detection method.
[0]
None = Silence detection option is disabled.
[1]
Packets Count = According to packet count.
Содержание Media Pack MP-11x
Страница 2: ......
Страница 14: ...User s Manual 14 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 24: ...User s Manual 24 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 25: ...Part I Getting Started with Initial Connectivity...
Страница 26: ......
Страница 35: ...Part II Management Tools...
Страница 36: ......
Страница 38: ...User s Manual 38 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 86: ...User s Manual 86 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 94: ...User s Manual 94 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 100: ...User s Manual 100 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 108: ...User s Manual 108 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 109: ...Part III General System Settings...
Страница 110: ......
Страница 118: ...User s Manual 118 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 121: ...Part IV General VoIP Configuration...
Страница 122: ......
Страница 152: ...User s Manual 152 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 202: ...User s Manual 202 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 204: ...User s Manual 204 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 230: ...User s Manual 230 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 231: ...Part V Gateway Application...
Страница 232: ......
Страница 234: ...User s Manual 234 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 274: ...User s Manual 274 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 278: ...User s Manual 278 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 298: ...User s Manual 298 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 326: ...User s Manual 326 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 327: ...Part VI Stand Alone Survivability Application...
Страница 328: ......
Страница 336: ...User s Manual 336 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 358: ...User s Manual 358 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 361: ...Part VII Maintenance...
Страница 362: ......
Страница 368: ...User s Manual 368 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 406: ...User s Manual 406 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 409: ...Part VIII Status Performance Monitoring and Reporting...
Страница 410: ......
Страница 441: ...Part IX Diagnostics...
Страница 442: ......
Страница 456: ...User s Manual 456 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 458: ...User s Manual 458 Document LTRT 65432 MP 11x MP 124 This page is intentionally left blank...
Страница 471: ...Part X Appendix...
Страница 472: ......
Страница 650: ...International Headquarters Contact us www audiocodes com info Website www audiocodes com Document LTRT 65432...