Copyright Asyril S.A.
Standard use of the Asycube Control URCap
Version: A2
24/50
The
Refresh
button, located at this level, allows the URCap to retrieve and reinitialize the
current warnings and alarms at any time.
Figure 3-17
– Refresh button to retrieve at any time warnings & alarms
The execution of a UR program is stopped each time a warning or an alarm is returned by the
Asycube platform. A popup is then displayed, inviting the user either to stop the program or to
continue it. In both cases, the warning or alarm is reinitialized by the Asycube platform.
The current list of warnings and alarms is the following:
Define
Type
Value
Comment
WARNING_FLASH
WARNING
0x0080
Flash operation fail
ALARM_PLATFORM
ALARM
0x0001
Above max temperature platform
ALARM_HOPPER
ALARM
0x0002
Above max temperature hopper (only for
Asycube 50/80)
ALARM_AMPLIFIER
ALARM
0x0004
Amplifier fault (only for Asycube 530)
ALARM_NO_S_POWER
ALARM
0x0010
No S-Power (only for Asycube 530)
ALARM_BACK_LT
ALARM
0x0040
Backlight timeout reached
Table 2- List of warnings and alarms