VP5000-DC/DC60, VP5000-DC/DC200-HL
Operation
Last edited 2019-02-08
by Sonja Scheunert
Filename
VP5000_DCDC60_200-HL_installation_manual_v1-4en.docx
151 / 173
CAUTION!
Risk of burns from hot surfaces
The housing heats up during operation.
•
Do not touch the housing until it has cooled sufficiently.
CAUTION!
Danger from noise
The VECTOPOWER generates noise during operation.
•
If necessary, wear hearing protection when working on or near the VECTOPOWER.
CAUTION!
Damage to health caused by coolant
The coolant contains glycol. Glycol is harmful to health.
•
Wear personal protective equipment if necessary: e.g., safety glasses, chemical-resistant
gloves.
•
Observe the information on the manufacturer’s safety data sheet.
1.
Check the device and the connection cables/wires for visible damage.
•
See chapter 7.7.2 Operation, Fault rectification, Checklist for malfunctions.
2.
Keep away from visible damage. Do not touch the damaged component. Avoid contact by
third parties. There is a risk that the damaged component is energized. Disconnect the
VECTOPOWER from the power supply immediately. Take measures to prevent unauthorized
reconnection. Inform the responsible specialist. See Chapter 7.7.3 Operation, Fault
rectification, Visible damage.
3.
If there is no visible damage, you can display the malfunction messages.
4.
Connect a computer to the VECTOPOWER.
5.
Have the faults displayed in VEConfig.
6.
Try to eliminate the displayed faults.
•
VEConfig provides descriptions of the displayed messages.
•
For further information, see the VEConfig operating manual, chapter Troubleshooting.
7.
Check the set parameters. See the VEConfig operating manual and the VE operating manual.