VP5000-DC/DC60, VP5000-DC/DC200-HL
Installation and commissioning
Last edited 2019-02-08
by Sonja Scheunert
Filename
VP5000_DCDC60_200-HL_installation_manual_v1-4en.docx
144 / 173
6.5.1
Preparing forming
You need the following parts and devices:
Required parts and devices
Specifications
DC voltage source
The voltage source should supply a voltage of
up to 800 V DC and a current of 100 mA.
Charging / discharging resistance
A resistance of 10
kΩ
/ 35 W is
recommended.
Relay
A relay with a changeover contact that can
switch 800 V DC at the power contacts is
recommended. It is possible to connect
another relay contact in series to achieve the
rated voltage.
Table 51: Required parts and devices for forming
Set up the circuit for the VECTOPOWER that you want to form.
Please note that the circuits for the different VECTOPOWER
types are designed differently:
•
The VECTOPOWER VP5000-DC/DC60 is connected to [/-]. See the figure below.
Figure 109: Design of the circuit for VECTOPOWER VP5000-DC/DC60
•
The VECTOPOWER VP5000-DC/DC200HL is connected to [DC+/-]. See the figure below.
Figure 110: Design of the circuit for VECTOPOWER VP5000-DC/DC200-HL