Trans-Cycle.
Transient Cycle count mode ON or OFF.
If the Trans-Cycle mode is ON, the transient programmed will repeat for the
specified number of cycles. Available setting range is from 0 through 9999.
A zero setting (0) indicates the transient will repeat indefinitely until
stopped by the operator using the
Test/Reset
key. Default setting is 1
(one).
Programming these four Transient parameters is done using the “Edit“ and “Change” soft-
keys using the same procedure for all parameters. When pressing the “Enter” after each
Change, the next Transient parameter screen appears. The four relevant screens are shown
below and provide the input parameter value upper and lower set point limits in the lower
part of each screen.
Example Transient Voltage Output
The following example shows the output drop created by the following Transient parameter
settings.
Parameter
Value
Value
Value
Output Voltage
150V
Trans-Site
25ms
Output Frequency
50 Hz
Trans-Time
1ms
Trans-Mode
ON
Trans-Cont.
OFF
Trans-Voltage
70V
Table 7-8: Programmed Voltage Drop Example Settings