CFS300 SERIES OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS300 Series Power Source Operation Manual
Page 101 of 156
6.14
MANUAL AC Mode Operation
To select MANUAL mode of operation, make sure the output is OFF first. Changing mode is
not possible while the output is active.
From the top level Menu, select the “
System
” soft key. This brings up the System menu. The
selected operating mode will be shown in the top left field as the first parameter entry.
6.14.1
Available Parameters in MANUAL Mode
In MANUAL mode, the following System parameters can be set from this screen:
•
Auto Run Mode
•
Out Mode
•
Alarm Volume
•
Contrast of LCD Display
•
Power Up Mode
•
Voltage High Limit
•
Voltage Low Limit
•
Frequency High Limit
•
Frequency Low Limit
•
Start Phase Angle
•
End Phase Angle
•
Results display Mode
•
Surge/Drop Mode
•
Over Current Protection Fold Back mode
•
Lock Mode
•
Memory Lock Mode
6.14.2
Programming MANUAL mode parameters
Programming in MANUAL mode is similar to programming steps in PROGRAM mode except
there is no step number to select as there is effectively only one “step” or setting. For
details on setting any of the MANUAL Mode parameters listed above, refer to the
corresponding in Section 6.12, “PROGRAM Mode - Step Parameter Details”.