Metering – AC Mode – Three & Two Phase Mode
MEASUREMENT SPECIFICATIONS - THREE & TWO PHASE MODE
MODEL
CFS330
CFS360
Frequency
Range
0.0 - 1000.0 Hz
Resolution
0.1 Hz
Accuracy
± 0.1Hz < 500Hz, ± 0.2Hz > 500Hz
Voltage AC
Range
0 – 420 Vrms
Resolution
0.1 V
Accuracy
± (0.2% of r 0.3V)
Current RMS
Range
L
0.005 - 1.200 A
0.005 - 2.400 A
H
1.00 - 13.00 A
2.00 - 26.00 A
Accuracy
L
± (1% of r 0.005 A)
CF < 1.5 and peak Curr.
≤ 3.6 A
± (1% of r 0.005 A)
CF < 1.5 and peak Curr.
≤ 7.2 A
H
± (1% of r 0.05 A)
CF < 1.5 and peak Curr.
≤ 27.6 A
± (1% of r 0.05 A)
CF < 1.5 and peak Curr.
≤ 55.2 A
Current Peak
Range
0.0 - 38.0 A
0.0 - 76.0 A
Accuracy
± (1% of r 0.5A @ 40.0-70.0 Hz
± (1.5% of r 1A @ 70.1 - 500 Hz
± (1.5% of r 1A @ 501 - 1000 Hz and CF<1.5
Power
Range
L
0.0 - 120.0 W
0.0 - 240.0 W
H
100 - 1300 W
200 - 2600 W
Accuracy
L
±(2% of 1.5 W) @ 40.0-500Hz, PF>0.2
±(2% of 3 W) @ 501-1000Hz, PF>0.5
H
±(2% of 5 W) @ 40.0-500Hz, PF>0.2
±(2% of 15 W) @ 501-1000Hz, PF>0.5
Power Factor
Range
0.000 - 1.000
Accuracy
W / VA, Calculated to 3 digits
App. Power
Range
L
0.0 - 120.0 VA
0.0 - 240.0 VA
H
100 - 1300 VA
200 - 2600 VA
Accuracy
V x A, Calculated
React. Power
Range
L
0.0 - 120.0 VAR
0.0 - 240.0 VAR
H
100 - 1300 VAR
200 - 2600 VAR