CFS300 SERIES OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS300 Series Power Source Operation Manual
Page 87 of 156
6.12.2
Memory Cycles
When using this feature, it is important to note the following characteristics of the CFS300
Series memory cycle function.
The Memory Cycle setting determines the number of cycles of the programmed frequency
that will be generated when the output is active.
Memory Cycle Range is from 0 to 9999 cycles. Settings of 0 and 1 have special meaning as
follows:
0:
“Continuous” setting. Indicates that the test cycle will repeat forever until
stopped by the operator.
1:
“Off” setting. Indicates that the test will perform only one cycle.
To change the Memory Cycle, use the number keypad to select the memory cycle range and
press the Enter soft key to accept the number. To cancel the editing of the Memory Cycle,
press the Esc soft key. When the Enter soft key is pressed and the Memory Cycle is
accepted, you transition into the next parameter: Memory.
Note:
The user can bypass editing this parameter and move to the next or previous
parameter set screen by pressing the “
Prev
” or “
Next
” soft key.
6.12.3
Voltage Programming
Each step can set a specific output voltage to be applied to the equipment under test. To set
a step voltage, select the “Voltage” parameter and press the “
Edit
” soft key. The voltage
setup screen will appear as shown below. This screen is the same as that used in the
MANUAL mode.
Available voltage settings are: