6.10.4
Single Step Modes
Pressing Enter after selecting the PROGRAM mode will bring up the Single Step parameter
setup screen. Available settings are shown in the bottom part of the screen.
Use the “
Change
” soft key to toggle between ON or OFF.
•
ON
= Program execution will take place in single step mode allowing the operator
to advance to each step from the front panel.
•
OFF
= Program execution will proceed automatically using the dwell times
programmed for each step.
When
Single Step
mode is
ON
, the source will sequence from one test step to the next
only when the Test/Reset key is pressed by an operator between each step. The source
will pause after each step has completed a test routine and passed based on the
programmed testing parameters. If a PASS result occurs for the step, the operator can
proceed to the next step in the sequence. If a FAIL result occurs for the step, the
operator will not be able to proceed in the test sequence. He will have to restart from
the beginning of the test sequence or step number one.
When the
Single Step
mode is
OFF
, the source will automatically sequence from one
step to the next, regardless if a pass or failure has occurred for a particular step.
6.10.5
Alarm Settings
Press the “
Enter
” soft key to confirm you selection. This brings up the Alarm parameter
setup screen. The Alarm parameter indicates the volume of the Alarm signal. Use the
numeric key pad to enter a value from 0 to 9 with 0 being OFF and 9 being loudest.