CFS300 SERIES OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2016 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CFS300 Series Power Source Operation Manual
Page 77 of 156
6.10.13
Voltage Sense Mode Settings
Press the “
Next
” soft key if needed to advance to the next parameter, the
Volt Sense
setting.
Available voltage sense modes are
INT
for internal sense and
EXT
for external or remote
voltage sense. For details on which mode is appropriate, refer to Section 6.12.4, “Voltage
Sense Modes”. Select the sense mode using the “
Change
” soft key. To save the setting,
press the “
Enter
” soft key. To cancel the editing, press the “
Esc
” soft key. When the “
Enter
”
soft key is pressed the
Mem
Lock
mode is accepted and you transition back to the next
system parameter.
6.10.14
External Trigger Out Settings
Use the Prev, Next soft keys to navigate to the Sync Signal parameter. Pressing the Edit
soft key will provide the following screen:
Ext trig:
indicates the Ext Trig that is programmed into the instrument.
Ext Trig Mode: indicates the Ext Trig mode that can be programmed into the instrument.
The Ext Trig Modes available are OFF, Start, END, and BOTH. Press the Change soft key to
toggle the mode. To save the parameter, press the Enter soft key. To cancel the editing of
the Ext Trig Mode, press the Esc soft key. When the Enter soft key is pressed the Ext Trig
Mode is accepted and you transition into the next system parameter: Auto Run.
If you wish to bypass editing this parameter and move to the next parameter you can press
the Prev or Next soft key.