18
-
English
CONTROL NK
CONTROL UNIT
BASE SYSTEM CONNECTIONS
4.
The base system components (control unit, power supply
unit, gear motor and emergency batteries) are pre-installed
on the NK module and connected to each other.
If replacing any parts, apply the connections illustrated
in Figs. 3-4-5.
Before powering the system, complete the installation
with the accessory devices. Correct functioning of the
automation requires the installation of the control device:
Key selector.
When you have fi nished ALL the connections, power the
system by following the indications in
STARTING UP
.
Information
NEVER remove the unit guard. Failure to comply with this
warning will render the warranty null and void!
NK CONTROL unit
4.1
NK CONTROL consists of the electronic control CARD, secured
to an extruded aluminium profi le which acts as SUPPORT for
securing it to the Automation Module. The card is protected by a
guard which has a port for accessing the programming and signal
devices while the terminal boards and connectors are directly
accessible at the sides (
fi g.6
).
Warning
!
NEVER remove the unit guard. Failure to comply with this
warning will render the warranty null and void!
ACCESSORY DEVICE CONNECTIONS
Completion of the installation requires connection of the
accessory devices used within the system. follow the specifi c
diagrams and instructions provided below.
Always make the connections with the power OFF.
Also disconnect the emergency batteries, if present! If a
device is replaced or added after setting-up and starting the
system, apply a system RESET.
Warning
!
All the command and control devices must be positioned
within sight of the automation, away from moving parts
and at a minimum height off the ground of 1.5 m.
Key selector (SC6 - SC6EC)
4.2
1
Connect the power supply cable to the numbered Key
selector terminal board, following the colours indicated
in
Tab.3
.
NOTE: to access the Key selector terminal board, refer to
the Key selector instructions.
2
Insert the Selector connector in
J7
on the NK CONTROL
card
(fi g.6)
.
Key selector
tab. 3 -
J6
K3
CONTROL
NK
K2
F20A
F5A
2 x
T3.15/[6.30]A
1
2
3
4
CONTROL
NK
A
1
2
3
4
F20A
card power supply rapid fuse
F5A
battery charger rapid fuse
T3,15A two delayed primary transfor-
mer fuses
POWER supply unit
mains power supply
230 V AC ±10% /
[115V on demand]
3x1 mmcable earthing cable included
Power supply unit
fi g. 3 -
B
fi g. 4 -
attery unit
Motor unit
fi g. 5 -
Cable colour
Terminal number
RED
1
GREEN
2
WHITE
3
PINK
4
GREY
5
LIGHT BLUE
6
BROWN
7
YELLOW
8
CONTROL
NK
(-)
(+)
5
6
K1
(5)
(6)
EMERGENCY BATTERIES
red
black