15
-
CONTROL NK
CONTROL UNIT
English
DESCRIPTION
1.
Envisaged use and fi eld of application
1.1
NK CONTROL
SYSTEM is used for electronic control of
NK
series sliding door automations.
The fi eld of application is limited to automatic doors with
one or two horizontal sliding wings used in civil, public or
industrial applications, in dry areas, in covered entrance
areas and foot traffi c passageways.
Warning
!
Do not use the product for purposes other than those
envisaged by the manufacturer or for any improper use.
Do not tamper with or modify the product.
The product must only be installed using APRIMATIC
material.
Warning
!
Keep children away from the operating range of the device
at all times.
Keep control devices in a safe place to prevent use by
children or unauthorised people.
Technical features and data
1.2
See
Tab.1
.
Before installing the product, check that the temperature
range marked on the drive is suitable for the location.
BASE SYSTEM COMPONENTS
See
fi g.1
.
1
CONTROL NK control unit
2
POWER SUPPLY unit
3
EMERGENCY BATTERY unit
4
24 VAC GEARMOTOR
ACCESSORY DEVICES
See
fig.2
for the ACCESSORY devices which can be
installed.
WARNING! Correct functioning of the automation requires
the installation of the control device: Key selector.
IMPORTANT! Also consult the specific instructions
supplied with each accessory.
POWER
SUPPLY
VOLTAGE
:
230 V ~ (+/- 10 % )
[115V
ON
DEMAND
]
EXTERNAL
DEVICE
VOLTAGE
: 24
V
CARD
PROTECTIONS
20 A rapid fuse for card power
supply
- short-circuit electronic
threshold at 45 A
POWER
SUPPLY
UNIT
PROTECTIONS
two 3.15/[6.3] A delayed fuses on
mains
A C C E S S O RY
P O W E R
SUPPLY
PROTECTION
PTC 1 A resettable fuse
TEMPERATURE
RANGE
:
- 20 ÷ + 70 °C
EMERGENCY
BATTERIES
:
two 12 V - 2 Ah batteries
-
maintenance-free -
BATTERY
-
CHARGER
built into CONTROL NK card
AUTOMATIC
DIAGNOSTICS
: buzzer
signals
SERIAL
COMMUNICATION
PORT
: RS
485
O P E N I N G
S P E E D
ADJUSTMENT
11 - 75 cm/s
(1 wing)
22 - 150 cm/s
(2 wings)
C L O S I N G
S P E E D
ADJUSTMENT
DIP SWITCH al 50%
11 - 50 cm/s
(1 wing)
22 - 100 cm/s
(2 wings)
DIP SWITCH al 100%
11 - 75 cm/s
(1 wing)
22 - 150 cm/s
(2 wings)
APPROACH
SPEED
:
SELF
-
LEARNED
(approx. 6 cm/s)
INVERSION
SENSITIVITY
: adjustable
DOOR
OPENING
TIME
0 - 45 sec. (continuously adjustable)
PARAMETERS
ADJUSTABLE
BY
TRIMMER
:
9
electric lock activation delay,
9
opening and closing appro-
aching speed,
9
thrust force (torque adjustment using current
control),
9
opened door pause time,
9
opening speed,
9
partial
wing opening percentage
PARAMETERS
ADJUSTABLE
BY
DIP
SWITCH
:
9
fixed or adaptive partial opening,
9
break-in response
enabling
,
9
master/slave mode enabling,
9
closing speed
(as percentage of opening speed)
,
9
photocell contact type,
9
emergency operation (opening or closing)
,
9
electric lock
enabling for “exit only” operation mode,
9
settings during power
failure: continuation or application of the last operation (using
emergency batteries)
,
9
settings if emergency batteries reach
critical threshold during power failure: >ast operation (opening
or closing), >electric lock maintained, >electric lock OFF.
Base components
fi g. 1 -
Technical features and data
tab. 1 -
3
2
1
4
Содержание CONTROL NK