Fault
Cause
FAULT
6
TROUBLESHOOTING
Fault
Cause
Remedy
The appliance does not
switch on
Fuse "blown"
Replace the fuse (see page 33)
Safety or protection device (safety
thermostat or overload cutout)
tripped
Press device reset button
Electronic circuit board damaged
Contact the after-sales service
Smell of gas
Gas leaks in supply system
Check the tightness of the system
Cooking cycle does not start
or stops suddenly
Control board electronic circuit board
damaged
Contact the after-sales service
Alarm triggered
Consult the "Key to Alarms" table
The burner does not light or
goes out suddenly
Gas valve faulty
Replace gas valve
Air intake in base obstructed
Clean the air intake
Burner does not light or goes
out suddenly with "GAS"
alarm signalled
Ignition plug wires disconnected or
damaged
Reconnect or replace the wires
Ignition plugs dirty or damaged
Clean or replace the plugs
Ignition monitoring device faulty
Replace the device