Use and installation manual
Adjust the floor-mounted feet
(A)
to level the appli-
ance.
Caution - warning
The connection must be made by authorised, skilled personnel, in accordance
with the relevant legal requirements, using appropriate and specified materials.
The appliance is supplied with operating voltage 230V/1N 50 Hz (230V/1N 60 Hz
available on request) (see attached wiring diagrams)
Before doing any work, cut off the mains electricity supply.
Connect the appliance to the mains electricity supply
as follows.
1 –
If not already present, install an automatic circuit-
breaker
(B)
, close to the appliance, with the following
characteristics.
–
Thermal breaker device (to adjust see table on
page 4)
–
Differential breaker set at 30 mA
–
Class B or C (IEC 898)
2 –
Undo the screws and remove the side panel
(A)
.
3 –
Connect the automatic circuit-breaker
(B)
to the
appliance's terminal board
(C)
and to the electrical
mains supply, in accordance with the electrical sys-
tem diagram provided at the back of the manual and
using a cable with the following characteristics.
–
Weight:
≥
than H05RN-F type (designation 245
IEC 57)
–
Temperature of use:
≥
70°C.
Important
When connecting, take care to connect the neu-
tral and earth lines.
4 –
Replace the panel and retighten the screws when the operation is complete.
LEVELLING
ELECTRICAL CONNECTION
IDM-39617701200.tif
A
IDM-39617701600.tif
B
C