If the problem or fault noticed is not amongst those
listed in the table, consult the "Key to Alarms" table
provided below.
The information provided below s intended to identify
the alarm signals which appear on the display (7).
Important
Press button (12) to reset the alarm and the cook-
ing cycle restarts automatically; if this is not the
case, press the start key (16).
TABLE OF ALARM INDICATIONS
Alarm
Fault
Remedy
Notes
H2O
No water in chamber, or water
pressure too low
Check that mains water is
present or adjust the pressure
(see page 32); if the problem
persists inform the after-sales
service
Convection cooking cycles can
still be carried out
H2O.
No water at drain, or water pres-
sure too low
Check that mains water is
present or adjust the pressure
(see page 32); if the problem
persists inform the after-sales
service
Convection and steam cooking
cycles can still be carried out
GAS
No mains gas, gas pressure too
low or flame detection failure
Press reset button (the button
may have to be pressed several
times); if the problem persists
inform the after-sales service
Stop cooking if this message is
repeated more than once
OPE
Oven door opening or closure
request
Open or close the oven door
Inform the after-sales service if
this message continues to be
displayed
The cooking cycle does not start
until the door has been opened
or closed as required