160
ARX 36-2 T4i, ARX 40-2 T4i , ARX 45-2 T4i
3.6 Lubrication and maintenance operations
3.6.50 Charging of the battery
• Only use chargers with an appropriate rated voltage. Check
that the charger is strong enough to charge the battery not
too strong to charge with excessive current.
• Read and observe the operating manual of the charger
manufacturer.
• Check that the ventilation holes in the battery cover are not
dirty or clogged and that gases can escape freely.
• Connect the positive terminal (+) of the battery to the posi-
tive terminal of the charger.
• Connect the negative terminal (-) of the battery to the nega-
tive terminal of the charger.
• Turn on the charger only after connecting the battery.
• Charge the battery with current corresponding to one tenth
of the battery capacity.
• After charging, first turn off the charger and then disconnect
the cables from the battery.
• The battery is fully charged, if:
- electric current and voltage remain constant in the case
of voltage-controlled chargers,
- the charging voltage in the case of current-controlled
chargers does not increase within two hours, the au-
tomatic charger turns off or switches to maintaining
charge.
Use rubber gloves and eye protection devices when han-
dling the battery.
Use suitable clothing to protect your skin against con-
tact with the electrolyte.
After eye contact with the battery electrolyte, immedi-
ately flush the affected eye thoroughly with running wa-
ter for several minutes. Then seek medical advice.
After ingestion of the electrolyte drink large quantities
of milk, water or suspension of magnesium hydroxide in
water.
In case of skin contact with electrolyte, remove your
clothing and shoes, wash the affected skin immediately
with soap and water or with solution of water and soda.
Then seek medical advice.
Do not eat, drink and smoke while working!
After completing the work, wash your hands and face
thoroughly with water and soap!
Do not check that a wire is live by touching the machine
frame.
When working with the battery always follow instruc-
tions of the battery manufacturer!
Never charge a frozen battery or battery with a tempera-
ture above 45 °C.
Stop charging if the battery is hot or leaking acid.
Check that the ventilation holes in the battery cover are
not dirty or clogged and that gases can escape freely. If
the ventilation holes are clogged, gases can accumulate
inside the battery and irreversibly damage it.
Never make direct conductive connection between both
poles of the battery to avoid a short circuit and a risk of
explosion of the battery.
Do not turn the battery upside down, the electrolyte can
flow out.
If the electrolyte is spilled, wash the affected area with
water and neutralize with lime.
Hand over the old inoperative battery for disposal.
Содержание 5953002
Страница 2: ......
Страница 6: ......
Страница 23: ...17 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i SPECIFICATION MANUAL Notes...
Страница 24: ...18 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i...
Страница 26: ...20 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i...
Страница 42: ...36 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i 588589A 2 3 Preservation and storage...
Страница 44: ...38 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i...
Страница 68: ...62 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i 12V 0 590A053 3 0 12V 1 2 4 2 7 Machine operation and use...
Страница 76: ...70 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i 2 7 Machine operation and use...
Страница 108: ...102 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i...
Страница 176: ...170 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i 3 7 Troubleshooting...
Страница 185: ...179 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i 1208392 MAINTENANCE MANUAL...
Страница 187: ...181 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i 1217529 MAINTENANCE MANUAL...
Страница 189: ...183 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i 1224119 MAINTENANCE MANUAL...
Страница 192: ...186 ARX 36 2 T4i ARX 40 2 T4i ARX 45 2 T4i 3 8 Appendix Notes...
Страница 193: ......