Introduction
The American Time SiteSync IQ Wired System offers the latest and most innovative way to incorporate synchronized time
throughout your facility, providing you with improved productivity and punctuality.
SiteSync IQ System Controller Standard Features
The SiteSync IQ System Controller provides synchronized control of system clocks and electrical circuits such as those for
controlling signaling devices and lights. Standard features include:
• Built-in keypad and LCD for setup and operation
• Internal clock accuracy of ±1 minute per year (without synchronization)
• Two level password security
• Automatic Daylight Saving Time and Leap Year correction
• Programmable Custom and Automatic Daylight Saving Time
• Support for time zone clocks (up to eight unique time zones)
The American Time SiteSync IQ wired clock series offers a selection of clocks to match a wide variety of application requirements.
Plastic case, steel case, analog and digital styles will provide years of maintenance-free service.
Mast
er Installation
Model No.
Standard
GPS
GPS Plus
Ethernet
2-Wire
Sync
SSQMSTR-
00
X
S
B
X
SSQMSTR-
00
X
S
GE
X
X
SSQMSTR-
00
X
S
G
X
X
SSQMSTR-
00
X
S
P
X
X
SSQMSTR-
00
X
S
PE
X
X
SSQMSTR-
00
X
S
E
X
X
Examples: SSQMSTR-00X6E has 6 signal circuits
SSQMSTR-00X8E has 6 signal circuits and 1 clock circuit
SSQMSTR-00X2E has 1 clock circuit
SiteSync IQ System Controller Optional Features
• Automatic time synchronization with one or more external time references,
including Ethernet and GPS
• Flexible control of 6 signal circuits
• Manual control of signal circuits
The following table shows the options included with each model number. The S in the model number
indicates the number of clock and signal relays (2, 6 or 8) that can be controlled by that model. Add
an R to the end of the Model No. to add the rack mount kit.
abcdefghijklmn
TUE JUL 03 2018
10:38:06 AM USCT
American Time
Status=AUTO ETH=Y
Glossar
y
App
endix
Tr
oublesho
oting
Clo
ck
Installation
Syst
em Contr
oller
Installation
Intr
oduction
Glossar
y
App
endix
Troublesho
oting
Clo
ck
Installation
Syst
em Contr
oller
Installation
Intr
oduction
SiteSync IQ Wired System Controller Specifications
Clock Circuit Fuses (2): ......... 8 amps, 250vac, subminiature
Signal Circuits (6): ................. Dry contacts rated at 240vac,
............Continuous: 7.5 amps resistive, 5 amps inductive,
............50% duty cycle*: 10 amps resistive
Physical Dimensions: ............ 5"h x 16
7
/
8
"w x 8"d
Temperature Range: .............
32˚-140˚F (0˚-60˚C)
Mounting: .............................. Desktop or rack mount
Communication: .................... Ethernet, RS-422 (GPS Plus) ,
................................................ RS-232 (Std GPS), Contact Closure
(2-wire) Sync
Shipping Weight: .................. 7
1
/
2
±
1
/
2
lbs.
Signal Circuits: ...................... 0 or 6 (optional)
Display: .................................. 128 x 64 graphics LCD
Keypad: .................................. 16 button tactile feedback
................................................ membrane switch
*50% duty cycle is defined as all signal relays on for one minute,
off for one minute, repeating
Input Voltage to Power Adapter: .......100-240vac, 50/60 Hz
Output Voltage from Power Adapter: ..........12.0 ±0.6 vdc
Peak Input Power: ..............................10 watts
Nominal Power: ..................................2.5 watts
Fuse: (Input Power) .............................8 amps, 250vac, Subminiature
Standby Timekeeping: .......................10 years
Memory/Time Backup: ......................CR2032 lithium battery,
240 mAh capacity
Timekeeping Accuracy: .....................±1 minute/year without correction
from GPS or Ethernet time reference
Program Retention: .........................................Unlimited
Programmable Events: ...................................9,999 events total
Schedules: .........................................................99 maximum
Signal Duration: .................................Programmable 1-9 seconds or
continuous On
Clock Circuits (2): ...............................Dry contacts rated at 250vac,
8 amps resistive, 5 amps inductive
UL Listed ....................................................File #E157522