background image

63

© American Time

© American Time

62

Glossar

y

App

endix

Tr

oublesho

oting

Clo

ck

Installation

Syst

em Contr

oller

 

Installation

Intr

oduction

Glossar

y

App
endix

Troublesho

oting

Clo
ck

Installation

Syst

em Contr

oller

Installation

Intr
oduction

SiteSync IQ Wired Installation Manual

SiteSync IQ Wired Installation Manual

© American Time

SiteSync IQ Installation Manual

SiteSync IQ Installation Manual

Appendix I: Clock Circuit

Wiring Diagrams

Appendix I: Clock Circuit Wiring 

Diagrams

Clock Code 07 - 2 wire Reverse Polarity Minute Impulse (59th minute)
Clock Code 08 - 2 wire Reverse Polarity Minute Impulse (59th minute ) with 12hr Correction
Clock Code 12 - Cincinnati D6 - 2 wire Reverse Polarity Minute Impulse (59th minute) with 12hr Correction
Clock Code 26 - Stromberg 2 wire Minute Impulse (58th minute) Hourly Correction Only

Clock Code 04 - Standard Electric Time AR-2A 2 wire Dual Voltage
Clock Code 17 - Standard Electric Time AR-2 2 wire Dual Voltage

Clock Code: 07, 08, 12, 26

*

*

Rectifier diode recommended for proper operation of reversing polarity.

Glossar

y

App

endix

Tr

oublesho

oting

Clo

ck

Installation

Syst

em Contr

oller

 

Installation

Intr

oduction

Glossar

y

App

endix

Tr

oublesho

oting

Clo

ck

Installation

Syst

em Contr

oller

 

Installation

Intr

oduction

Glossar

y

App
endix

Troublesho

oting

Clo
ck

Installation

Syst

em Contr

oller

Installation

Intr
oduction

Clock Code: 04, 17

Clock Code 15 - Straight Frequency Electronic Clock

Clock Code 21 - Cincinnati D1

Clock Code 22 - Dukane Synchronous Wired

Clock Code: 15

Clock Code: 21

Clock Code: 22

Содержание SiteSync IQ SSQMSTR-00XSB

Страница 1: ...Installation and Operation Manual Part H004095W Rev 10 SiteSync IQ Wired System...

Страница 2: ...led by qualified persons in conformance with applicable national and local electrical codes Improper installation of this equipment can result in lethal electrical shock and fire Disconnect and lock o...

Страница 3: ...external time references including Ethernet and GPS Flexible control of 6 signal circuits Manual control of signal circuits The following table shows the options included with each model number The S...

Страница 4: ...ing Procedure Set Menu DST LOCAL Set DST Auto 8 Auto 9 Custom 0 Off OK Accept Set Menu Bias LOCAL Enter Time Zone offset from UTC 11 30 OK Accept Set Menu LOCAL Time Zone Code 05 99 Custom USCT Scroll...

Страница 5: ...0 AM AM PM OK ACPT 10 11 12 13 9 8 Set Menu DST LOCAL DST Start Mar 30 Start Time 01 00 AM AM PM OK ACPT Set Menu DST LOCAL Define DST By 1 Fixed Dates 2 Floating Dates 7 6 For use only when configuri...

Страница 6: ...uide Press O to exit the Sync Now function Screen 28 will be displayed when the Setup Wizard has been completed You will no longer be prompted on power up for the setup information The System Controll...

Страница 7: ...ed Reception may be displayed by pressing or d Press O if signal was received to view number of connected satellites Note If you see the number of satellites in view press OBB to return to the Main Sc...

Страница 8: ...o 1500 ft than the Standard GPS option Recommended Glossary Appendix Troubleshooting Clock Installation System Controller Installation Introduction Glossary Appendix Troubleshooting Clock Installation...

Страница 9: ...os as necessary This is the subnet mask of your network Press O d Use the keypad to enter the Gateway IP Enter preceding zeros as necessary This is the IP address of your network s Gateway device Pres...

Страница 10: ...leshooting Clock Installation System Controller Installation Introduction existing equipment existing equipment Rx IQ System Controller Transmitting IQ System Controller surge protector switch NC NC C...

Страница 11: ...anual correction of impulse secondary clocks and 2 Simple synchronization of the system controller to an external time source Adjust Time Choose 1 Adjust System Clks 2 Ethernet Sync Now Adjust System...

Страница 12: ...er of the schedule for the new event and press O d If any events have already been assigned to the selected schedule the days and start time for the first event are displayed Use the key to move to th...

Страница 13: ...ute Press for AM or for PM Press O to accept the event start time xProgramming Schedule Change Events Event Menu Choose 1 Set Date 1 31 2 Set Weekday s 4e Event Menu Enter Event Month Month 02 Februar...

Страница 14: ...enu Time Sort MTWTF 05 03 AM Sch 01 Event 0000 Scroll OK Edit Event Menu Time Sort Hour 24 Scroll OK Edit Event Menu WKD sort View Weekday MON Sch 01 Event 0000 Scroll OK Edit Event Menu View Events b...

Страница 15: ...tatus AUTO ETH Y TUE JUL 03 2018 10 38 06 AM USCT American Time Status AUTO ETH Y Programming Signal Circuits Keypad Interface Optional signal relays for controlling signal or lighting circuits must b...

Страница 16: ...ntly configured to ON or OFF in the Circuit Durations Menu the circuit will toggle states when pressing the MAN key This feature can be used to turn on lights after a power outage For example parking...

Страница 17: ...the lower right hand corner must be pressed for any changes to take effect Time Zone This drop down contains a list of all time zones Daylight Saving Time This drop down contains AUTO CUSTOM or OFF G...

Страница 18: ...be pressed for changes to take effect a Schedule This is the schedule that the circuit will switch to at the specified date time b Date Time This is the date time in which the schedule for the circuit...

Страница 19: ...ion directly connect an Ethernet patch cable from the system controller to a computer that is on the same Subnet Example Set the connecting computer IP address to 192 168 10 11 See your Network Admini...

Страница 20: ...y of time synchronization of the system controller The Update button must be pressed for changes to take effect 7 Time Display Format This allows the user to change the Time Display Format on the LCD...

Страница 21: ...at corresponds to your time sync priority b Enter the minutes and seconds that the System Controller should attempt to synchronize each hour to the time sync option chosen Clock Code From the Config M...

Страница 22: ...g Guide 9 Lost or forgotten User Lock Contact American Time Technical Support at the number listed below 10 SiteSync IQ System Controller locks up or display goes blank Use a pen small screwdriver or...

Страница 23: ...know how to do this If the problem cannot be resolved after following these steps please call Technical Support at American Time at 800 328 8996 Comm Menu Client 1 Enable 2 Disable OK Done Comm Menu...

Страница 24: ...ill serve DHCP addresses If no DHCP server is present or fails to receive an address the SiteSync IQ system controller will default to 192 168 10 10 Try connecting to the SiteSync IQ system controller...

Страница 25: ...circuit s you wish to test and press the M key to trigger the applicable relay s d Observe the LED s next to the circuit relays being tested If they light up when the circuit is being triggered verif...

Страница 26: ...e on a network server or various workgroup computers To set up your computer or other device to synchronize to the IQ System Controller simply enter the IP address of the IQ System Controller as the t...

Страница 27: ...09 USA Indiana East 5 5 NO 10 USA Mountain MST MDT 7 6 YES 11 USA Pacific PST PDT 8 7 YES 12 USA Midway Island Samoa SST 11 11 NO 13 USA Wake Islands WAKT 11 11 NO 14 UTC 0 0 0 CONFIG 15 UTC 1 1 1 CON...

Страница 28: ...O to accept time Step 14 5 for event duration Step 15 O to accept duration Step 16 O to save event At this point to program a new event for the same schedule days and duration simply Press 1 and enter...

Страница 29: ...ss B to exit Event Menu Press B again to exit Program Menu if programming is complete Status Menu Software Ver 1 00 Created 2013 05 28 OK Done Status Menu Serial Number 001160010000 OK Done Status Men...

Страница 30: ...A B C D E F G G H J K L M N P R Front Back u Insert USB drive into the bottom slot of Port A nNote Ensure USB drive only contains the BIN file v Enter Service Lock when prompted Press O w Press O to u...

Страница 31: ...ontroller Installation Introduction Clock Code 01 3 wire Synchronous Clock Code 03 Standard Electric Time Dual Motor Clock Code 06 Synchronous Wired 2 Clock Code 09 Simplex 59th Minute Dual Motor Cloc...

Страница 32: ...6 2 wire Reverse Polarity Minute Impulse 59th minute with 12hr Correction Clock Code 26 Stromberg 2 wire Minute Impulse 58th minute Hourly Correction Only Clock Code 04 Standard Electric Time AR 2A 2...

Страница 33: ...Appendix I Clock Circuit Wiring Diagrams Glossary Appendix Troubleshooting Clock Installation System Controller Installation Introduction Appendix I Clock Circuit Wiring Diagrams Glossary Appendix Tr...

Страница 34: ...rds and Technology The Time and Frequency Division part of NIST s Physics Laboratory maintains the standard for frequency and time interval for the United States and provides official time to the Unit...

Отзывы: