The Remote Connect Web Interface allows remote access to your SiteSync IQ system controller via a web browser. This includes Event 

and Circuit programming, manual circuit activation, time/date settings and other system configurations.

This feature is available to all SiteSync IQ System Controllers with the Ethernet option.

Note:

 Java SE Runtime Environment (JRE) 7 Update 7 will need to be installed to run the Events Applet.

–This can also be downloaded at http://www.java.com/en/
–Ensure that you have the most current web browser (ie. Firefox, Internet Explorer, Chrome)

To access Remote Connect:

 

1.  Ensure that the SiteSync IQ System Controller installation has been performed (page 6) and that the Ethernet option has been   

 

 

configured (pages 18-19)

 

2.  Open a web browser. Enter the IP address for your system controller (#4 on page 18) as http://xxx.xxx.xxx.xxx or ssiq plus last    

 

 

six digits of MAC address if DHCP is Enabled in the web browser’s Address field (Figure 1). Press the 

Enter

 key.

 

 

   

 

    or

 
 

 

Figure 1

Note:

  If using DHCP Host Name, the network or computer connected to the system controller for configuration must be on the same 

Subnet for Host Name to work properly.

Note:

  If the Remote Transmitter is on a network without a DHCP server, the default address of the Remote Transmitter will be 

192.168.10.10. In this situation, directly connect an Ethernet patch cable from the Remote Transmitter to a computer that is on the same 

Subnet. Example: Set the connecting computer IP address to 192.168.10.11. See your Network Administrator if you do not know how to 

do this.
 

3.  A User Login window, (Figure 2) will appear. There are two available user names, 

uclock

 and 

sclock

, which represent the user    

 

and service access levels. The user security level allows access to everything but the Configuration Tab. 

  

User Level Access:

   Enter 

uclock

 in lowercase letters in the 

User Name

 field and 

uclock

 in the 

Password

 field. This is a user login which will allow    

 

 

access to time/date and event menus.

  

Service Level Access:

   Enter 

sclock

 in lowercase letters in the 

User Name

 field and 

sclock

 in the 

Password

 field. This is a service login which will  

 

 

 

allow access to all menus.

 

 

**Passwords may be changed in the Configuration Tab.

 

 

Then, click the 

Login

 button.

 

 

Figure 2

 
4.  The Remote Connect utility will appear with the 

General

 tab selected. The tabs displayed may differ depending on the  

 

 

 

configuration of the unit. 

 

 

Figure 3

For more details on the features of Remote Connect, click on the Support link in the upper right-hand corner of the utility (Figure 3).

Wired Signal Circuit Option

TUE JUL 03 2018
10:38:06 AM USCT
American Time
Status=AUTO    ETH=Y

For circuits configured for ON/OFF operation:

If  the default duration for a circuit being activated with the MAN function is currently configured to ON or OFF (in the Circuit Durations 

Menu) the circuit will toggle states when pressing the MAN key. This feature can be used to turn on lights after a power outage. For example, 

parking lot lighting is set up on Circuit 6 with a continuous ON event at 10:00pm, and an OFF event at 6:00am. The power goes out due to 

a thunderstorm at 2:00am and comes back on at 3:00am. These parking lot lights will be off, since the unit was reset. To turn them back on 

after 3:00am, you can activate circuit 6 via the MAN button, as described on the previous page. The lights will then stay on until the OFF 

event at 6:00am.

Automatically switching assigned schedules for a circuit:

This feature allows for programming of a schedule change on any circuit. This 

may be handy for setting a holiday schedule, for example:

To program an automatic schedule change:

1. Press 

P3

, enter User Lock (if applicable), then press 

1

. The circuit 

  schedule assignments screen will display.

2.  Press circuit (1-6) you wish to set automatic schedule change for.

3. Press 

M

 button to enter a schedule change.

4. Option 

1

 and 

2

 are schedule replacements. This allows for reverting

  back to the current schedule at a later date.

5. Select 

1

 or 

2

. In this screen, use the 

<>

 keys to select the schedule 

  to change to. Press 

O

.

6.  In this screen, enter the date with the keypad. Press 

O

 after entry of each

  field to advance. For example, press 

O

 after entering the year to

  advance to the month field. AM/PM can be selected with the 

<>

 keys.

 Press 

O

 when date and time have been entered.

7.  Repeat these steps for another schedule change on this circuit. Choose
 option 

2

 if option 

1

 was initially set or vice versa. These options will

  occur chronologically by the date and time entered for each.

To see a programming example, see Appendix D.

w

Controlling Signal Circuits Manually

Signal circuits can be controlled manually with the MAN key acting as a momentary push-button switch. To initiate manual control:

a. Press 

M

, enter User Lock (unless User Lock is disabled) and 

 press 

O

 (unless User Lock is disabled).

b.  Press any combination of keys 1-6 to select or deselect the circuits to be
   turned on with the 

M

 key.

 

Wired Circuit Activation:

   

Press and hold the 

M

 key to activate the selected circuits for the desired length of time.

   

Release the 

M

 key.

  

Note:

 When the wireless circuit activation is enabled, the wired activation will have approximately a 3 second delay to  

 

   

account for the wireless transmission.

The 

M

 key can be pressed as many times as needed. Control of the signal circuits reverts to its previous state (AUTO or OFF) upon exiting 

this menu.
 

Wireless Circuit Activation:

   

Press 0 to enable wireless circuit activation. Press 

M

 to activate the selected circuits for the default duration of circuit 6. 

  

Note:

 Reference Setting Signal Circuit Schedule and Duration on Page 29 to change the default duration of circuit 6.

  

Note:

 Upon pressing 

M

, a TX will appear in the upper right hand corner to signify that the wireless activation is being transmitted.

  

Note:

 The wired circuit will be delayed in this mode.

Manual Signal 

 

       TX

Select Circuits:  0=WL     7=All

Circuit:    1234567

Man=Signal                      OK=Exit

Circuit Menu

Select Circuits 

1

Circ  1     2     3     4     5     6

Sch   01    01    04    --    --    --

Circuit Menu

Circuit  1   :   Sch 01

MAN=Timed  Sch Change

<>=Scroll Ok=Accept

Circuit Menu

Timed Sch Change for

Circuit  1   :   Sch   01

1=Sch05 2=Empty

Time Sched Change to

Sch:05   on   2014-10-31

 

    at   08:00  AM

<>=Scroll OK=Next

Time Sched Change to

Sch:05   on   2014-10-31

 

    at   08:00  AM

<>=AM/PM OK=Next

3b

2

3

4

5

6

Содержание SiteSync IQ SSQMSTR-00XSB

Страница 1: ...Installation and Operation Manual Part H004095W Rev 10 SiteSync IQ Wired System...

Страница 2: ...led by qualified persons in conformance with applicable national and local electrical codes Improper installation of this equipment can result in lethal electrical shock and fire Disconnect and lock o...

Страница 3: ...external time references including Ethernet and GPS Flexible control of 6 signal circuits Manual control of signal circuits The following table shows the options included with each model number The S...

Страница 4: ...ing Procedure Set Menu DST LOCAL Set DST Auto 8 Auto 9 Custom 0 Off OK Accept Set Menu Bias LOCAL Enter Time Zone offset from UTC 11 30 OK Accept Set Menu LOCAL Time Zone Code 05 99 Custom USCT Scroll...

Страница 5: ...0 AM AM PM OK ACPT 10 11 12 13 9 8 Set Menu DST LOCAL DST Start Mar 30 Start Time 01 00 AM AM PM OK ACPT Set Menu DST LOCAL Define DST By 1 Fixed Dates 2 Floating Dates 7 6 For use only when configuri...

Страница 6: ...uide Press O to exit the Sync Now function Screen 28 will be displayed when the Setup Wizard has been completed You will no longer be prompted on power up for the setup information The System Controll...

Страница 7: ...ed Reception may be displayed by pressing or d Press O if signal was received to view number of connected satellites Note If you see the number of satellites in view press OBB to return to the Main Sc...

Страница 8: ...o 1500 ft than the Standard GPS option Recommended Glossary Appendix Troubleshooting Clock Installation System Controller Installation Introduction Glossary Appendix Troubleshooting Clock Installation...

Страница 9: ...os as necessary This is the subnet mask of your network Press O d Use the keypad to enter the Gateway IP Enter preceding zeros as necessary This is the IP address of your network s Gateway device Pres...

Страница 10: ...leshooting Clock Installation System Controller Installation Introduction existing equipment existing equipment Rx IQ System Controller Transmitting IQ System Controller surge protector switch NC NC C...

Страница 11: ...anual correction of impulse secondary clocks and 2 Simple synchronization of the system controller to an external time source Adjust Time Choose 1 Adjust System Clks 2 Ethernet Sync Now Adjust System...

Страница 12: ...er of the schedule for the new event and press O d If any events have already been assigned to the selected schedule the days and start time for the first event are displayed Use the key to move to th...

Страница 13: ...ute Press for AM or for PM Press O to accept the event start time xProgramming Schedule Change Events Event Menu Choose 1 Set Date 1 31 2 Set Weekday s 4e Event Menu Enter Event Month Month 02 Februar...

Страница 14: ...enu Time Sort MTWTF 05 03 AM Sch 01 Event 0000 Scroll OK Edit Event Menu Time Sort Hour 24 Scroll OK Edit Event Menu WKD sort View Weekday MON Sch 01 Event 0000 Scroll OK Edit Event Menu View Events b...

Страница 15: ...tatus AUTO ETH Y TUE JUL 03 2018 10 38 06 AM USCT American Time Status AUTO ETH Y Programming Signal Circuits Keypad Interface Optional signal relays for controlling signal or lighting circuits must b...

Страница 16: ...ntly configured to ON or OFF in the Circuit Durations Menu the circuit will toggle states when pressing the MAN key This feature can be used to turn on lights after a power outage For example parking...

Страница 17: ...the lower right hand corner must be pressed for any changes to take effect Time Zone This drop down contains a list of all time zones Daylight Saving Time This drop down contains AUTO CUSTOM or OFF G...

Страница 18: ...be pressed for changes to take effect a Schedule This is the schedule that the circuit will switch to at the specified date time b Date Time This is the date time in which the schedule for the circuit...

Страница 19: ...ion directly connect an Ethernet patch cable from the system controller to a computer that is on the same Subnet Example Set the connecting computer IP address to 192 168 10 11 See your Network Admini...

Страница 20: ...y of time synchronization of the system controller The Update button must be pressed for changes to take effect 7 Time Display Format This allows the user to change the Time Display Format on the LCD...

Страница 21: ...at corresponds to your time sync priority b Enter the minutes and seconds that the System Controller should attempt to synchronize each hour to the time sync option chosen Clock Code From the Config M...

Страница 22: ...g Guide 9 Lost or forgotten User Lock Contact American Time Technical Support at the number listed below 10 SiteSync IQ System Controller locks up or display goes blank Use a pen small screwdriver or...

Страница 23: ...know how to do this If the problem cannot be resolved after following these steps please call Technical Support at American Time at 800 328 8996 Comm Menu Client 1 Enable 2 Disable OK Done Comm Menu...

Страница 24: ...ill serve DHCP addresses If no DHCP server is present or fails to receive an address the SiteSync IQ system controller will default to 192 168 10 10 Try connecting to the SiteSync IQ system controller...

Страница 25: ...circuit s you wish to test and press the M key to trigger the applicable relay s d Observe the LED s next to the circuit relays being tested If they light up when the circuit is being triggered verif...

Страница 26: ...e on a network server or various workgroup computers To set up your computer or other device to synchronize to the IQ System Controller simply enter the IP address of the IQ System Controller as the t...

Страница 27: ...09 USA Indiana East 5 5 NO 10 USA Mountain MST MDT 7 6 YES 11 USA Pacific PST PDT 8 7 YES 12 USA Midway Island Samoa SST 11 11 NO 13 USA Wake Islands WAKT 11 11 NO 14 UTC 0 0 0 CONFIG 15 UTC 1 1 1 CON...

Страница 28: ...O to accept time Step 14 5 for event duration Step 15 O to accept duration Step 16 O to save event At this point to program a new event for the same schedule days and duration simply Press 1 and enter...

Страница 29: ...ss B to exit Event Menu Press B again to exit Program Menu if programming is complete Status Menu Software Ver 1 00 Created 2013 05 28 OK Done Status Menu Serial Number 001160010000 OK Done Status Men...

Страница 30: ...A B C D E F G G H J K L M N P R Front Back u Insert USB drive into the bottom slot of Port A nNote Ensure USB drive only contains the BIN file v Enter Service Lock when prompted Press O w Press O to u...

Страница 31: ...ontroller Installation Introduction Clock Code 01 3 wire Synchronous Clock Code 03 Standard Electric Time Dual Motor Clock Code 06 Synchronous Wired 2 Clock Code 09 Simplex 59th Minute Dual Motor Cloc...

Страница 32: ...6 2 wire Reverse Polarity Minute Impulse 59th minute with 12hr Correction Clock Code 26 Stromberg 2 wire Minute Impulse 58th minute Hourly Correction Only Clock Code 04 Standard Electric Time AR 2A 2...

Страница 33: ...Appendix I Clock Circuit Wiring Diagrams Glossary Appendix Troubleshooting Clock Installation System Controller Installation Introduction Appendix I Clock Circuit Wiring Diagrams Glossary Appendix Tr...

Страница 34: ...rds and Technology The Time and Frequency Division part of NIST s Physics Laboratory maintains the standard for frequency and time interval for the United States and provides official time to the Unit...

Отзывы: