Use the keypad to enter the DNS IP. This is the IP address of your network's DNS
server. Enter preceding zeros as necessary.
• DNS IP:
• Press
O
Use the keypad to use Manual IP's or a DNS IP for the same server.
• Press
1
for Manual IP
• Press
2
for DNS IP
Press
O
to accept
If you choose Manual IP, continue to
If you choose DNS IP, skip to
Use the keypad to enter the Time Server address. Enter preceding
zeros as necessary.
• Time Server Address:
• Press
O
OR Press
O
to accept the default set at the factory from the list of known
good Internet Time Servers in Appendix A.
Use the keypad to enter the Alternate Time Server address. Enter preceding
zeros as necessary.
• Alt. Time Server Address:
• Press
O
OR Press
O
to accept the default set at the factory from the list of known
good Internet Time Servers in Appendix A.
This shows the currently selected time server DNS address.
Use Remote Connect to change this value (see page 37).
• Press
O
The unit will prompt you to enter the Port Number. This is
remote web access and should be set to 0080.
• Port Number:
0080
• Press
O
to accept the default (80) set at the factory
To confirm proper set up, sync each option.
• Press
8
to sync.
• a. If successful "Sync Successful" will display.
• b. If not successful, "Sync Failed" will display.
Refer to the troubleshooting guide.
• Press
O
to exit the Sync Now function.
Screen 28 will be displayed when the Setup Wizard has been completed. You will no
longer be prompted on power-up for the setup information.
The System Controller should now show the correct time and date on its display screen.
Your System Controller is now set up for proper operation.
You can continue to the other sections of this manual for further information on other
features. If you have any questions or problems that cannot be resolved by following the
steps in the Troubleshooting Guide, please contact Technical Support at American Time
(800-328-8996)
.
System Controller Setup
Wizard
Glossar
y
App
endix
Tr
oublesho
oting
Clo
ck
Installation
Syst
em Contr
oller
Installation
Intr
oduction
User Notes
Glossar
y
App
endix
Troublesho
oting
Clo
ck
Installation
Syst
em Contr
oller
Installation
Intr
oduction
TUE JUL 03 2018
10:38:06 AM USCT
American Time
Status=AUTO ETH=Y
TUE JUL 03 2018
10:38:06 AM USCT
American Time
Status=AUTO ETH=Y
Programming Procedure
(cont)
21
21
22
23
Comm Menu
Enter DNS IP
008.008.008.008
<=Bksp
OK=Done
22
23
24
25
26
27
28
Comm Menu
Time Server Entry
1=Manual IP
2=(DNS IP)
Ok=Done
Comm Menu
Time Server Address
131.107.013.100
<=Bksp
OK=Done
23
25
24
25
Comm Menu
Alt Time Srvr Addr
173.014.055.009
<=Bksp
Ok=Done
Time Server DNS
3.americantime.pool
.ntp.org
Ok=Next
Comm Menu
Enter Port Number
for web access: 80
OK=Done
26
Set Menu
Ethernet Sync
Failed
Set Menu
Ethernet Sync
Successful
Set Menu
Time Sync Option is
Available: Ethernet
8=Sync now
OK=Set
27b (example)
27a (example)
27 (example)
Setup Wizard
Successfully Completed