![Amazone Precea 3000-A Скачать руководство пользователя страница 174](http://html1.mh-extra.com/html/amazone/precea-3000-a/precea-3000-a_original-operating-manual_2919773174.webp)
10.1.22 Clean the singling unit
INTERVAL
Every 10 operating hours
or
daily
Keep the singling unit head free of dust, deposits, and
foreign objects.
NOTE
Under very dusty operating conditions, the
inspection interval must be shortened.
1.
Open the locks
1
.
2.
Remove the cover
2
.
3.
Clean the inside of the cover with a brush.
1
2
CMS-I-00001909
4.
Release the lock
1
until the points
2
are
aligned.
1
2
CMS-I-00001910
5.
remove the singling disc
1
from the drive hub.
6.
Clean the singling unit housing.
7.
Install the singling disc.
1
CMS-I-00001912
CMS-T-00003718-A.1
10 | Repairing the machine
Maintaining the machine
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE
168