![Amazone Precea 3000-A Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/amazone/precea-3000-a/precea-3000-a_original-operating-manual_2919773106.webp)
Flow rate
Valve position
Pressure
1 bar
1.5 bar
2 bar
2.5 bar
3 bar
3.5 bar
4 bar
1
0.43 l/mi
n
0.53 l/min
0.61 l/min
0.68 l/min
0.74 l/min
0.8 l/min
0.86 l/min
2
0.61 l/mi
n
0.75 l/min
0.87 l/min
0.97 l/min
1.06 l/min
1.15 l/min
1.23 l/min
3
0.97 l/mi
n
1.19 l/min
1.37 l/min
1.53 l/min
1.68 l/min
1.81 l/min
1.94 l/min
4
1.4 l/min
1.71 l/min
1.98 l/min
2.21 l/min
2.42 l/min
2.62 l/min
2.8 l/min
5
2.15 l/mi
n
2.63 l/min
3.04 l/min
3.4 l/min
3.72 l/min
4.02 l/min
4.3 l/min
6
3.1 l/min
3.8 l/min
4.38 l/min
4.9 l/min
5.37 l/min
5.8 l/min
6.2 l/min
7
3.97 l/mi
n
4.87 l/min
5.62 l/min
6.28 l/min
6.88 l/min
7.43 l/min
7.95 l/min
8
5.06 l/mi
n
6.19 l/min
7.15 l/min
7.99 l/min
8.76 l/min
9.46 l/min
10.11 l/min
3.
Depending on the set pump pressure,
read the valve position from the table above.
4.
Move the valve
1
to the desired position.
5.
Since the flow rate depends on the applied
material,
check the setting by calibrating.
Observe the operating manual for the liquid
fertiliser tank
NOTE
The determined values are reference values.
Check the setting each time the applied
material is changed.
During application in the seed furrow, liquid
fertiliser can drip out of the application point in
the headland position.
CMS-I-00002735
6 | Preparing the machine
Preparing the implement for operation
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE