![Amazone Precea 3000-A Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/amazone/precea-3000-a/precea-3000-a_original-operating-manual_2919773124.webp)
2.
To interrupt the fertiliser flow on implements
with distributor heads and single row control,
Actuate the coupling rod
1
on the rows to be
removed.
1
CMS-I-00007404
3.
To fix the flap in the position:
Install the bolt
2
.
4.
For a conversion from 6 to 4 rows
disconnect the setting motors
1
for rows 2 to 6
from the wiring harness
or
For a conversion from 12 to 8 rows
disconnect the setting motors for rows 3 to 12
from the wiring harness.
Ro
w
1
2
3
4
5
6
7
8
9
10 11 12
Connection
A
B
C
D
E
F
G
H
Dust
protection cap
A
B
C
D
E
F
Dust protection cap
5.
For a conversion from 6 to 4 rows
connect the setting motors for rows 2 to 6 to the
wiring harness according to the table
or
For a conversion from 12 to 8 rows
connect the setting motors for rows 3 to 12 to the
wiring harness according to the table.
6.
Seal the free connection cable with a dust cap.
1
2
CMS-I-00007403
6 | Preparing the machine
Preparing the implement for operation
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE
118