10.1.18 Cleaning the fertiliser hopper
INTERVAL
Every 100 operating hours
or
Every 12 months
REQUIREMENTS
The implement is coupled to the tractor
The tractor and implement are secured
1.
Switch off the filling auger
2.
Switch off the fan.
3.
Climb onto the loading board using the steps.
or
To unfold the ladder, see "Operating the loading
board with ladder".
Climb onto the loading board using the ladder.
4.
Open the rubber straps
1
.
5.
Open the fertiliser hopper tarpaulin
2
.
6.
Remove residues or foreign objects from the
fertiliser hopper.
CMS-I-00001892
7.
Insert the unlocking tool
1
into the lock.
8.
To open the protective screens,
unlock the lock and swivel the protective screen
upwards by the handle
2
.
9.
Remove residues or foreign objects from the
fertiliser hopper.
10. Close the protective screen.
11. Park the unlocking tool on the fertiliser hopper.
1
2
CMS-I-00002028
CMS-T-00002392-B.1
10 | Repairing the machine
Maintaining the machine
MG6659-EN-GB | F.1 | 25.10.2022 | © AMAZONE