GreenDrill control terminal 5.2
64
GreenDrill BAH0108-0 03.20
6.7.1
Calibration by driving a calibration distance
1. On the field, measure out a calibration distance of exactly
100 m.
Mark the start and end point of the calibration distance.
2. Drive the tractor to the starting position and put the carrying
implement into working position.
3. Select the display with the
buttons.
4. Confirm the selection with the
button.
5. Confirm the display with the
button.
6. Actuate the
button and drive exactly the calibration
distance.
7. Stop after exactly 100 m and press the
button.
Display when the calibration is complete
If no button is pressed, the display switches to the Main menu
after approx. 5 seconds.