Fault message
Description
Remedy
Fan
with hydraulic drive
and pressure sensor
is not rotating
Control lamp
without function.
Back pressure in the return flow
is too high (see section 5.8.1,
page
48).
The fan is not rotating
Switch off control terminal.
Check if
foreign objects are hindering
the
rotation of the fan
the chute
is installed wrong
(see section 5.7, page 47)
Fan motor
with electric drive
is connected
is not overloaded
is not rotating.
Switch off control terminal.
Contact the service partner.
The fan motor
with electric drive
is not wired correctly
Check the cables and plug
connections to the fan motor.